Specifications

1716
kW
kW
kW
A
dB(A)
CMM
Pa
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power Consumption
COP
Energy label
Inrush current (Max. running current)
Sound Ievel
*1
Air flow
Static pressure
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
Outdoor
Indoor
Outdoor
50Hz/60Hz
Height x Width x Depth
1Phase 220-240V 50Hz, 1Phase 220V 60Hz 3Phase 380-415V 50Hz, 3Phase 380V 60Hz
FDUM140VNXVD
FDUM140VD
FDC140VNX
FDUM125VNXVD
FDUM125VD
FDC125VNX
FDUM125VSXVD
FDUM125VD
FDC125VSX
FDUM140VSXVD
FDUM140VD
FDC140VSX
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
CLASS
A
A
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB. External static pressure
of indoor units is 60Pa.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Models FDUM100V,125V,140VD
FDUM
DUCT CONNECTED
-Middle Static pressure-
FDUM 50/60/71/
100/125/140VD
Outline drawing(Unit:mm)
Model FDUM50VD
Models FDUM60V,71VD
RC-E4
(Option)
Wired
remote control
RCH-E3
(Option)
Drain can be discharged
upwards by 600mm from
the ceiling surface. It
allows a piping layout
with a high degree of
freedom Depending on
the installation location.
Point
2
600mm Drain Pump
Flexible hose
less than
600mm
Point
1
Various Adaptability
Selectable static pressure and
Flexible duct design with
selectable air suction (direct
suction /duct suction) can meet
wide pattern of installation.
model
50/60/71VD
100VD
125/140VD
Standard
50
60
60
Max
85
90
85
Static pressure Pa (50Hz)
12.5
(5.0~14.0)
14.0
(4.0~17.0)
3.62/3.77
3.45/3.71
A/A
14.0
(5.0~16.0)
16.0
(4.0~18.0)
4.34/4.69
3.23/3.41
A/B
350x1,370x635
59
Procure locally
Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E
1,300x970x370
105
Rotary
4.5(30)
9.52/15.88
100
30
15
5(26)
12.5
(5.0~14.0)
14.0
(4.0~18.0)
3.62/3.77
3.45/3.71
A/A
14.0
(5.0~16.0)
16.0
(4.0~20.0)
4.34/4.69
3.23/3.41
A/B
5(15)
Filter kit
UM-FL1E : for 50
UM-FL2E : for 60, 71
UM-FL3E : for 100, 125, 140
(option)
external static pressure loss:5pa
Cooling:48 Heating:50 Cooling:49 Heating:52
Cooling:48 Heating:50 Cooling:49 Heating:52
-15~43*
2
Cooling
Heating
O/U is higher
O/U is lower
Operating
temperature range
Ref.piping length
Vertical height
difference
Exterior dimensions
Net weight
Type of compressor
Ref.amount precharged
Ref.piping size
Height x Width x Depth
Liquid/Gas
Hi:38 Me:36 Lo:33 Hi:38 Me:36 Lo:33
Hi:28 Me:25 Lo:22
kW
kW
kW
A
dB(A)
CMM
Pa
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power Consumption
COP
Energy label
Inrush current (Max. running current)
Sound Ievel
*1
Air flow
Static pressure
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
Outdoor
Indoor
Outdoor
50Hz/60Hz
Height x Width x Depth
FDUM50ZIXVD
FDUM50VD
SRC50ZIX-S
FDUM60ZIXVD
FDUM60VD
SRC60ZIX-S
1Phase 220-240V 50Hz, 1Phase 220V 60Hz
FDUM71VNVD
FDUM71VD
FDC71VNX
5.0
(2.2~5.6)
5.4
(2.5~6.3)
1.52/1.41
3.29/3.83
A/A
5.6
(2.8~6.3)
6.7
(3.1~7.1)
1.86/1.96
3.01/3.42
B/B
7.1
(3.2~8.0)
8.0
(3.6~9.0)
2.14/2.16
3.32/3.70
A/A
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
5(14)
-20~20
2.95(30)
50
750x880(+88)x340
60
-15~43*
2
-15~20
1.4(15)
6.35/12.7
30
20
20
640x800(+71)x290
43
Scroll
40
Cooling
Heating
O/U is higher
O/U is lower
Operating
temperature range
Ref.piping length
Vertical height
difference
Exterior dimensions
Net weight
Type of compressor
Ref.amount precharged
Ref.piping size
Height x Width x Depth
Liquid/Gas
Procure locally
Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E
Standard:50/40, Max:85/100 Standard:60/60, Max:90/100Standard:50/40, Max:85/90
Hi:16 Me:15 Lo:14
Hi:20 Me:18 Lo:15
299x750x635
34
Hi:13 Me:12 Lo:11
48
5(17)
Hi:35 Me:32 Lo:29
Cooling:51 Heating:48
FDUM100VNXVD
FDUM100VD
FDC100VNX
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.72/2.95
3.68/3.80
A/A
4.5(30)
100
1,300x970x370
105
Hi:28 Me:25 Lo:22
5(24)
Hi:37 Me:35 Lo:32
Cooling:48 Heating:50
47
Hi:34 Me:31 Lo:28
Powerful-Hi can be selected. Sound level: 50ZIXVD 35dB, 60ZIXVD 38dB, 71VNXVD 38dB, 100/125/140VNXVD 41dB, 100/125/140VSXVD 41dB
Air flow: 50ZIXVD 14CMM, 60ZIXVD 18CMM, 71VNXVD 23CMM, 100/125/140VNXVD 34CMM, 100/125/140VSXVD 34CMM
Cooling:60 Heating:50 100
RCN-KIT3-E
(Option)
Wireless
remote control
299x950x635
40
350x1,370x635
59
Rotary
30
15
9.52/15.88
Standard:60/60, Max:90/100
FDUM100VSXVD
FDUM100VD
FDC100VSX
10.0
(4.0~11.2)
11.2
(4.0~16.0)
2.72/2.95
3.68/3.80
A/A
Hi:37 Me:35 Lo:32
100
Standard:60/55, Max:85/100 Standard:60/55, Max:85/100
-20~20
[ INDOOR UNIT ]