Due to optimization of outlet design of air flow with our 
new advanced technology, sufficient air flow is secured 
and long reach of air flow is realized.(FDT)
For person who is far 
from the indoor unit
For both persons who are 
feeling hot or cold
Can cool both the kitchen 
and the guests
Expansion of outlet air flow area realizes 
reduction of pressure loss caused by air flow 
in the indoor unit. Load of fan motor is 
decreased and efficiency is increased.
• Reduction of air flow pressure loss
Previous
New
Shape of heat exchanger
365mm
298
mm
FDT125~140
18%
reduction!!
• Increase of heat transfer efficiency
Applying high efficient piping in heat exchanger and 
optimization of heat exchanger (2parts 1part) 
increases heat transfer efficiency.
Individual flap control system 
According to room temperature conditions, four 
directions of air flow can be controlled individually by 
following Flap control system. 
As individual flap control is available even after 
installation, installation area became wider than before.
The thinnest design
Thanks to new design of heat exchanger changed from 2 parts to 1 part, the height of 
indoor unit is reduced drastically. 
based on 50% capacity of FDT100V in heating operation
Air-conditioners are generally selected with the operation under the most severe ambient temperature conditions.
The inverter constantly adjusts compressor output to meet the exact demand of the indoor units.
 i.e. In case that selecting the capacity of an inverter air-conditioner based on heating operation at -5°C, its capacity drops by 
50% at 7°C(ISO-TI measurement condition) and operation period at 50% capacity is normally longer than that at 100% of 
nominal heating capacity.
Considering annual electrical power consumption of inverter air-conditioners, it is quite important to give the first priority to 50% 
actual capacity and selecting inverter air-conditioners is the best solution for saving energy and protecting the environment. 
High efficiency
Achieved COP 5.67
Selected 
upper position
Max swing 
range
Selected 
lower position
Flap control system
The flap can swing within the range of upper and 
lower flap position selected with wired remote control.
(this system is applied for FDEN, SRK type also)
*
Wireless remote control and RCH-E3 is not applicable to the Individual flap 
control system and the Flap control system.