Specifications
39
R410A
A
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
*
2
Outdoor
Outdoor
Indoor
*
2
Outdoor
Height x Width x Depth
Height x Width x Depth
Liquid/Gas
Cooling
Heating
Cooling
Heating
kW
kW
kW
A
dB(A)
dB(A)
CMM
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
3Phase 380-415 50Hz, 3Phase 380V 60Hz
SRK100VSPZJX
SRK125VSPZJX SRK140VSTZJX
SRK50ZJX-S1
FDC100VS
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.72/2.86
3.62/3.92
A/A
SRK60ZJX-S1
FDC125VS
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.25/4.29
2.94/3.26
C/C
SRK50ZJX-S1
FDC140VS
14.0
(5.0~14.5)
16.0
(4.0~16.5)
4.53/4.05
3.09/3.95
B/A
The data are measured under the following conditions (ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB.
Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : The values are for one indoor unit operation.
*
3 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power consumption
COP
Energy label
Inrush current (Max. running current)
Sound pressure
Ievel*
1
Sound power level
*
1
Air flow
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
Exterior dimensions
Net weight
Ref.amount precharged
Ref.piping size
15m
15m15m
The values are for simultaneous Multi operation.
Set model name
Twin Triple
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
*
2
Outdoor
Outdoor
Indoor
*
2
Outdoor
Height x Width x Depth
Height x Width x Depth
Liquid/Gas
Cooling
Heating
Cooling
Heating
kW
kW
kW
A
dB(A)
dB(A)
CMM
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
1Phase 220-240 50Hz, 1Phase 220V 60Hz 3Phase 380-415 50Hz, 3Phase 380V 60Hz
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power consumption
COP
Energy label
Inrush current (Max. running current)
Sound pressure
Ievel*
1
Sound power level
*
1
Air flow
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
Exterior dimensions
Net weight
Ref.amount precharged
Ref.piping size
The values are for simultaneous Multi operation.
Set model name
Twin Triple Twin Triple
SRK60ZJX-S1
FDC125VNX
12.5
(5.0~14.0)
14.0
(4.0~17.0)
3.60/3.48
3.47/4.02
A/A
SRK50ZJX-S1
FDC140VNX
14.0
(5.0~16.0)
16.0
(4.0~18.0)
3.98/3.68
3.52/4.35
A/A
SRK60ZJX-S1
FDC125VSX
12.5
(5.0~14.0)
14.0
(4.0~18.0)
3.60/3.48
3.47/4.02
A/A
SRK50ZJX-S1
FDC140VSX
14.0
(5.0~16.0)
16.0
(4.0~20.0)
3.98/3.68
3.52/4.35
A/A
SRK125VNXPZJX
SRK140VNXTZJX
SRK100VNXPZJX SRK125VSXPZJXSRK100VSXPZJX
SRK140VSXTZJX
100
309x890x220
15
Polypropylene net x2 (Washable)
Wired:RC-E5, RCH-E3 & Interface kit:SC-BIKN-E
1,300x970x370
105
4.5(30)
9.52/15.88
100
30
15
-15~43
*
3
-20~20
Cooling:75,Heating:73
309x890x220
15
Polypropylene net x2 (Washable)
Wired:RC-E5, RCH-E3 & Interface kit:SC-BIKN-E
845x970x370
3.8(30)
9.52/15.88
50
30
15
-15~43
*
3
-20~20
5 (24) 5 (15)
Ref.piping length
Vertical height
difference
Operating
temperature range
Cooling
Heating
O/U is higher
O/U is lower
Ref.piping length
Vertical height
difference
Operating
temperature range
Cooling
Heating
O/U is higher
O/U is lower
1Phase 220-240 50Hz, 1Phase 220V 60Hz
SRK140VNTZJX
SRK100VNPZJX
SRK125VNPZJX
SRK50ZJX-S1
FDC140VN
14.0
(5.0~14.5)
16.0
(4.0~16.5)
4.53/4.05
3.09/3.95
B/A
SRK50ZJX-S1
FDC100VN
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.72/2.86
3.62/3.92
A/A
SRK60ZJX-S1
FDC125VN
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.25/4.29
2.94/3.26
C/C
Twin Triple
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
49
70
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
Hi:51 Me:43 Lo:32
Hi:48 Me:44 Lo:36
Cooling:50,Heating:51
72
Hi:14.5 Me:12.5 Lo:8.5
Hi:17.5 Me:15 Lo:11
5 (24)
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
51
73
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
49
70
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
Hi:51 Me:43 Lo:32
Hi:48 Me:44 Lo:36
Cooling:50,Heating:51
72
Hi:14.5 Me:12.5 Lo:8.5
Hi:17.5 Me:15 Lo:11
5 (15)
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
51
73
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
Hi:51 Me:43 Lo:32
Hi:48 Me:44 Lo:36
70
SRK50ZJX-S1
FDC100VNX
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.66/2.60
3.76/4.31
A/A
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
70
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
Cooling:49 Heating:52
72
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
Hi:51 Me:43 Lo:32
Hi:48 Me:44 Lo:36
70
SRK50ZJX-S1
FDC100VSX
10.0
(4.0~11.2)
11.2
(4.0~16.0)
2.66/2.60
3.76/4.31
A/A
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
70
Hi:47 Me:42 Lo:29
Hi:48 Me:42 Lo:36
Cooling:49 Heating:52
72
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
81 83
Micro Inverter
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
Hi:14.5 Me:12.5 Lo:8.5
Hi:17.5 Me:15 Lo:11
Cooling:48 Heating:50
Hi:13.5 Me:11 Lo:8
Hi:17.0 Me:14.5 Lo:10.5
Hi:14.5 Me:12.5 Lo:8.5
Hi:17.5 Me:15 Lo:11
Cooling:48 Heating:50