Specifications

31
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : The values are for one indoor unit operation.
*
3 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Indoor unit
Outdoor unit
Range of
usage
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power consumption
COP
Energy label
Inrush current (Max. running current)
Sound pressure
Ievel*
1
Sound power level
*
1
Air flow
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Exterior dimensions
Net weight
Panel
Air filter, Q'ty
Remote control(option)
kW
kW
kW
A
dB(A)
dB(A)
CMM
mm
kg
kg
kg(m)
ø
m
m
m
O/U
O/U
SPECIFICATIONS
1Phase 220-240V 50Hz, 1Phase 220V 60Hz
FDT100VNPVF
Twin Triple
FDT125VNPVF
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.94/3.09
3.40/3.62
A/A
12.5
(5.0~14.0)
14.0
(4.0~16.0)
3.95/3.70
3.16/3.78
B/A
14.0
(5.0~14.5)
16.0
(4.0~16.5)
4.51/4.58
3.10/3.49
B/B
FDT140VNTVF
FDT140VNPVF
27.5(Unit:22 Panel:5.5)
29.5(Unit:24 Panel:5.5)
5(24)
Cooling:75 Heating:73
845x970x370
3.8(30)
FDT50VF
FDC100VN
FDT60VF
FDC125VN
FDT50VF
FDC140VN
FDT71VF
FDC140VN
14.0
(5.0~14.5)
16.0
(4.0~16.5)
4.65/4.63
3.01/3.46
B/B
27.5(Unit:22 Panel:5.5)
FDT100VSPVF
FDT50VF
FDC100VS
Twin
FDT125VSPVF
FDT60VF
FDC125VS
29.5(Unit:24 Panel:5.5)
FDT140VSPVF
FDT71VF
FDC140VS
Unit:246x840x840 Panel:35x950x950
T-PSA-3BW-E
Pocket Plastic net x1 (Washable)
Wired:RC-EX1A, RC-E5, RCH-E3 Wireless:RCN-T-36W-E
The values are for simultaneous Multi operation.
Hi:18 Me:16 Lo:14
3Phase 380-415V 50Hz, 3Phase 380V 60Hz
3Phase 380-415V 50Hz, 3Phase 380V 60Hz
Indoor unit
Outdoor unit
Range of
usage
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power consumption
COP
Energy label
Inrush current (Max. running current)
Sound pressure
Ievel*
1
Sound power level
*
1
Air flow
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
kW
kW
kW
A
dB(A)
dB(A)
CMM
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
Exterior dimensions
Net weight
Panel
Air filter, Q'ty
Remote control(option)
SPECIFICATIONS
20.0
(7.0~22.4)
22.4
(7.6~25.0)
6.58/6.02
3.04/3.72
B/A
5(19)
FDT250VSPVF
FDT200VSPVF
Cooling:150 Heating:145
Unit:298x840x840 Panel:35x950x950
32.5(Unit:27 Panel:5.5)
1,300x970x370
122
5.4(30)
9.52/22.22
1,505x970x370
140
7.2(30)
12.7/22.22
70
FDT125VF
FDC250VS
Triple Double TwinTwin
FDT140VSTVF
FDT50VF
FDC140VS
FDT200VSTVF
FDT71VF
FDC200VS
FDT100VF
FDC200VS
25.0
(10.0~28.0)
28.0
(9.5~31.5)
8.30/7.75
3.01/3.61
B/A
5(22)
14.0
(5.0~14.5)
16.0
(4.0~16.5)
4.65/4.63
3.01/3.46
B/B
5(15)
Unit:246x840x840 Panel:35x950x950
20.0
(7.0~22.4)
22.4
(7.6~25.0)
6.49/6.12
3.08/3.66
B/A
5(19)
20.0
(7.0~22.4)
22.4
(7.6~25.0)
6.58/6.15
3.04/3.64
B/A
5(19)
25.0
(10.0~28.0)
28.0
(9.5~31.5)
8.28/7.70
3.02/3.64
B/A
5(22)
FDT200VSDVF
FDT50VF
FDC200VS
FDT250VSDVF
FDT60VF
FDC250VS
The values are for simultaneous Multi operation.
T-PSA-3BW-E
Pocket Plastic net x1 (Washable)
Wired:RC-EX1A, RC-E5, RCH-E3 Wireless:RCN-T-36W-E
1,300x970x370
122
5.4(30)
9.52/22.22
9.52/15.88
50
30
15
-15
~
43*
3
-20
~
20
Ref.piping length
Vertical height
difference
Operating
temperature range
Cooling
Heating
O/U is higher
O/U is lower
Exterior dimensions
Net weight
Ref.amount precharged
Ref.piping size
Height x Width x Depth
Unit+Panel
Liquid/Gas
Hi:33
Me:31 Lo:30
49
70
51
Cooling:50 Heating:51
72
Hi:35
Me:33 Lo:31
Hi:33
Me:31 Lo:30
Hi:33
Me:31 Lo:30
Hi:35
Me:33 Lo:31
49
70
5(15)
Hi:33
Me:31 Lo:30
Hi:33
Me:31 Lo:30
51
73
Cooling:50 Heating:51
72
Hi:21
Me:19 Lo:17
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.94/3.09
3.40/3.62
A/A
12.5
(5.0~14.0)
14.0
(4.0~16.0)
3.95/3.70
3.16/3.78
B/A
14.0
(5.0~14.5)
16.0
(4.0~16.5)
4.51/4.58
3.10/3.49
B/B
Indoor
*
2
Outdoor
Outdoor
Indoor
*
2
Outdoor
Hi:18 Me:16 Lo:14
73
Hi:21
Me:19 Lo:17
73
Hi:18
Me:16 Lo:14
30
15
-15
~
43*
3
Operating
temperature range
Cooling
Heating
O/U is higher
O/U is lower
Ref.piping length
Vertical height
difference
Exterior dimensions
Net weight
Ref.amount precharged
Ref.piping size
Liquid/Gas
Height x Width x Depth
845x970x370
83
3.8(30)
9.52/15.88
50
1,505x970x370
140
7.2(30)
12.7/22.22
27.5(Unit:22 Panel:5.5)
Hi:33
Me:31 Lo:30
51
73
Hi:42
Me:40 Lo:37
Cooling:57 Heating:58
74
Hi:40
Me:37 Lo:35
57
74
29.5(Unit:24 Panel:5.5)
Hi:21
Me:19 Lo:17
Cooling:150 Heating:145
Hi:35
Me:33 Lo:31
57
74
27.5(Unit:22 Panel:5.5)
Hi:18
Me:16 Lo:14
Cooling:150 Heating:145
Hi:33
Me:31 Lo:30
57
74
29.5(Unit:24 Panel:5.5)
Hi:33
Me:31 Lo:30
Cooling:57 Heating:58
74
Height x Width x Depth
Unit+Panel
Indoor
*
2
Outdoor
Outdoor
Indoor
*
2
Outdoor
Hi:27
Me:24 Lo:20
Hi:30
Me:27 Lo:23
Hi:18
Me:16 Lo:14
Cooling:75 Heating:73
70
Powerful-Hi can be selected. Sound level: 200/250VSPVF 51dB, 140VSTVF 39dB, 200VSTVF 46dB, 200VSDVF 39dB, 250VSDVF 46dB
Air flow: 200/250VSPVF 37CMM, 140VSTVF 20CMM, 200VSTVF 28CMM, 200VSDVF 20CMM, 250VSDVF 28CMM
Powerful-Hi can be selected. Sound level: 100VNPVF 39dB, 125/140VNPVF 46dB, 140VNTVF 39dB, 100VSPVF 39dB, 125/140VSPVF 46dB
Air flow: 100VNPVF 20CMM, 125/140VNPVF 28CMM, 140VNTVF 20CMM, 100VSPVF 20CMM, 125/140VSPVF 28CMM
R410A
A
Micro Inverter
81 83
Micro Inverter
-15
~
20 -20
~
20 -15
~
20