Specifications

26
R410AR410A
CLASS
A
AA
RCN-KIT3-E
Wireless remote control (Option)
FDF
FLOOR STANDING
[ INDOOR UNIT ]
Micro Inverter
FDF 100/125/140VD
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
Outdoor
Outdoor
Indoor
Outdoor
Height x Width x Depth
kW
kW
kW
A
dB(A)
dB(A)
CMM
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
FDF125VNVD
FDF140VNVD
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
1 Phase 220-240 50Hz, 1Phase 220V 60Hz
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.40/4.36
2.84/3.21
C/C
5(24)
14.0
(5.0~14.5)
16.0
(4.0~16.5)
5.15/5.31
2.72/3.01
D/D
51
73
FDF100VNVD
FDF125VD
FDC125VN
FDF140VD
FDC140VN
FDF100VD
FDC100VN
10.0
(4.0~11.2)
11.2
(4.0~12.5)
3.12/3.10
3.21/3.61
A/A
49
70
FDF100VSVD
FDF125VSVD
3 Phase 380-415V 50Hz, 3Phase 380V 60Hz
FDF140VSVD
FDF100VD
FDC100VS
FDF125VD
FDC125VS
FDF140VD
FDC140VS
10.0
(4.0~11.2)
11.2
(4.0~12.5)
3.12/3.10
3.21/3.61
A/A
49
70
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.40/4.36
2.84/3.21
C/C
5(15)
14.0
(5.0~14.5)
16.0
(4.0~16.5)
5.15/5.31
2.72/3.01
D/D
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB.
Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power consumption
COP
Energy label
Inrush current (Max. running current)
Sound pressure
Ievel
*1
Sound power level
*1
Air flow
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
Hi:50 Me:48 Lo:44
Operating
temperature range
Cooling
Heating
O/U is higher
O/U is lower
Ref.piping length
Vertical height
difference
Exterior dimensions
Net weight
Type of compressor
Ref.amount precharged
Ref.piping size
Height x Width x Depth
Liquid/Gas
Rotary
3.8(30)
9.52/15.88
50
30
15
-15~43
*
2
-20~20
81 83
Cooling:50 Heating;51
72
Cooling:50 Heating;51
72
51
73
Cooling:75 Heating:73
1850x600x320
52
Plastic net x1(washable)
wired:RC-E4 installed wireless:RCN-KIT3-E
845x970x370
Hi:26 Me:23 Lo:19
Powerful-Hi can be selected. Sound level:100/125/140VNVD 54dB, 100/125/140VSVD 54dB
Air flow: 100/125/140VNVD 29CMM, 100/125/140VSVD 29CMM
Micro Inverter