Specifications

25
R410A
A
Remote control (Option)
R410AR410A
CLASS
A
AA
FDEN 100/125/140VF
RCN-E1R
Wireless
RC-E5RC-EX1A
Wired
RCH-E3
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
Outdoor
Outdoor
Indoor
Outdoor
Height x Width x Depth
kW
kW
kW
A
dB(A)
dB(A)
CMM
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
FDEN125VNVF
FDEN140VNVF
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
1Phase 220-240V 50Hz, 1Phase 220V 60Hz
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.45/4.08
2.81/3.43
C/B
5(24)
14.0
(5.0~14.5)
16.0
(4.0~16.5)
5.80/4.92
2.41/3.25
E/C
250x1,620x690
49
FDEN100VNVF
FDEN125VF
FDC125VN
FDEN140VF
FDC140VN
FDEN100VF
FDC100VN
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.85/2.97
3.51/3.77
A/A
FDEN100VSVF FDEN125VSVF
3Phase 380-415V 50Hz, 3Phase 380V 60Hz
FDEN140VSVF
FDEN100VF
FDC100VS
FDEN125VF
FDC125VS
FDEN140VF
FDC140VS
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.85/2.97
3.51/3.77
A/A
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.45/4.08
2.81/3.43
C/B
5(15)
14.0
(5.0~14.5)
16.0
(4.0~16.5)
5.80/4.92
2.41/3.25
E/C
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB.
Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power consumption
COP
Energy label
Inrush current (Max. running current)
Sound pressure
Ievel
*1
Sound power level
*1
Air flow
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
Hi:46 Me:44 Lo:43 Hi:46 Me:44 Lo:43
Operating
temperature range
Cooling
Heating
O/U is higher
O/U is lower
Ref.piping length
Vertical height
difference
Exterior dimensions
Net weight
Type of compressor
Ref.amount precharged
Ref.piping size
Height x Width x Depth
Liquid/Gas
50
30
15
-15~43
*
2
-20~20
Rotary
3.8(30)
9.52/15.88
845x970x370
81 83
Hi:44
Me:41 Lo:39
49
70
Hi:26
Me:23 Lo:21
Cooling:50 Heating:51
72
Pocket Plastic net x2 (Washable)
Wired:RC-EX1A, RC-E5, RCH-E3 Wireless:RCN-E1R
51
73
Hi:44
Me:41 Lo:39
49
70
Hi:26
Me:23 Lo:21
Cooling:50 Heating:51
72
51
73
Cooling:75 Heating:73
Hi:29 Me:26 Lo:23 Hi:29 Me:26 Lo:23
Powerful-Hi can be selected. Sound level: 100VNVF 46dB, 125/140VNVF 50dB, 100VSVF 46dB, 125/140VSVF 50dB
Air flow: 100VNVF 28CMM, 125/140VNVF 32CMM, 100VSVF 28CMM, 125/140VSVF 32CMM
FDEN
CEILING SUSPENDED
Micro Inverter