Specifications

2726
Standard Inverter
[ INDOOR UNIT ]
4way
FDT
Low/Middle Static pressure
FDUM
High Static pressure
FDU FDEN
FDF
Wired
RC-E5 RCH-E3RC-EX1A
Remote control (Option)
Wireless
RCN-KIT3-E
(For FDU, FDUM, FDF)
RCN-E1R
(For FDEN)
RCN-TC-36W-E
(For FDT)
Filter kit (option)
UM-FL2EF : for 71
UM-FL3EF : for 100
(For FDUM)
external static pressure loss:5Pa
CEILING CASSETTE DUCT CONNECTED CEILING SUSPENDED
FLOOR STANDING
SRK
WALL MOUNTED
SPECIFICATIONS
SPECIFICATIONS
(For FDT, FDU, FDUM, FDE, SRK)
SPECIFICATIONS
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Powerful-Hi can be selected. Sound level: FDF71VNPVD1 42dB, FDF90VNPVD1 54dB Air flow: FDF71VNPVD1 20
m
3
/min
, FDF90VNPVD1 29
m
3
/min
Powerful-Hi for FDT can be selected. Sound level : FDT71VNPVF1 46dB(A), FDT90VNPVF1 51dB(A) Air flow : FDT71VNPVF1 28m
3
/min, FDT90VNPVF1 37m
3
/min
Powerful-Hi for FDU can be selected. Sound level : FDU71VNPVF1 38dB(A), FDU90VNPVF1 44dB(A) Air flow : FDU71VNPVF1 24m
3
/min, FDU90VNPVF1 36m
3
/min
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Powerful-Hi for FDUM can be selected. Sound level : FDUM71VNPVF1 38dB(A), FDUM90VNPVF1 44dB(A) Air flow : FDUM71VNPVF1 24m
3
/min, FDUM90VNPVF1 36m
3
/min
Powerful-Hi for FDEN can be selected. Sound level : FDEN71VNPVF1 50dB(A), FDEN90VNPVF1 46dB(A) Air flow : FDEN71VNPVF1 20m
3
/min, FDEN90VNPVF1 28m
3
/min
NEW
Dimensions (Unit:mm)
Standard Inverter
Set model name
FDF71VNPVD1 FDF90VNPVD1 SRK71VNPZM
Indoor unit FDF71VD1 FDF100VD1 SRK71ZM-S
Outdoor unit FDC71VNP FDC90VNP FDC71VNP
Power source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Nominal cooling capacity (Min~Max) kW 7.1 ( 1.4 ~ 7.1 ) 9.0 ( 1.9 ~ 9.0 ) 7.1 ( 1.4 ~ 7.1 )
Nominal heating capacity (Min~Max) kW 7.1 ( 1.0 ~ 7.1 ) 9.0 ( 1.5 ~ 9.0 ) 7.1 ( 1.0 ~ 7.1 )
Power consumption Cooling/Heating kW 2.63 / 2.08 2.79 / 2.25 2.36 / 1.88
EER/COP Cooling/Heating 2.70 / 3.41 3.23 / 4.00 3.01 / 3.78
Inrush current 220/230/240 V
A
5 5 5
Max. running current 14.5 18.0 14.5
Sound power
level*
1
Indoor Cooling/Heating
dB(A)
61 / 61 65 / 65 60 / 61
Outdoor
Cooling/Heating 67 / 67 69 / 69 67 / 67
Sound
pressure
level*
1
Indoor
Cooling (Hi/Me/Lo)
39 / 35 / 33 50 / 48 / 44 49 / 45 / 39 / (Ulo) 26
Heating (Hi/Me/Lo)
39 / 35 / 33 50 / 48 / 44 46 / 43 / 38 / (Ulo) 35
Outdoor
Cooling/Heating 54 / 54 57 / 55 54 / 54
Air flow
Indoor
Cooling (Hi/Me/Lo)
m
3
/min
18 / 16 / 14 26 / 23 / 19 17.5 / 14 / 8
Heating (Hi/Me/Lo)
18 / 16 / 14 26 / 23 / 19 19.5 / 15.5 / 14
Outdoor
Cooling/Heating 36 / 36 63 / 49.5 36 / 36
Exterior
dimensions
Indoor
HeightxWidthxDepth
mm
1,850 x 600 x 320 318 x 1,098 x 248
Outdoor
640 x 800 x 290 750 x 880 x 340 640 x 800 x 290
Net weight
Indoor
kg
49 52 16
Outdoor
45 57 45
Ref.piping size
Liquid/Gas ømm 6.35 / 12.7 6.35 / 15.88 6.35 / 12.7
Refrigerant line (one way) length m 23 30
Vertical height differences
Outdoor is higher/lower
m Max.20 / Max.20
Outdoor operating
temperature range
Cooling
°C
-15~46*
2
Heating -15~20
Air filter, Q'ty Plastic net x1(Washable) Polypropylene net (Washable) x2
Remote control (option) wired:RC-E5 installed wireless:RCN-KIT3-E wired:RC-EX1A, RC-E5, RCH-E3
Standard Inverter
Set model name
FDUM71VNPVF1 FDUM90VNPVF1 FDEN71VNPVF1 FDEN90VNPVF1
Indoor unit FDUM71VF1 FDUM100VF1 FDEN71VF1 FDEN100VF1
Outdoor unit FDC71VNP FDC90VNP FDC71VNP FDC90VNP
Power source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Nominal cooling capacity (Min~Max) kW 7.1 ( 1.4 ~ 7.1 ) 9.0 ( 1.9 ~ 9.0 ) 7.1 ( 1.4 ~ 7.1 ) 9.0 ( 1.9 ~ 9.0 )
Nominal heating capacity (Min~Max) kW 7.1 ( 1.0 ~ 7.1 ) 9.0 ( 1.5 ~ 9.0 ) 7.1 ( 1.0 ~ 7.1 ) 9.0 ( 1.5 ~ 9.0 )
Power consumption Cooling/Heating kW 2.63 / 1.96 2.65 / 2.25 2.50 / 1.96 2.75 / 2.25
EER/COP Cooling/Heating 2.70 / 3.62 3.40 / 4.00 2.84 / 3.62 3.27 / 4.00
Inrush current 220/230/240 V
A
5 5 5 5
Max. running current 14.5 18.0 14.5 18.0
Sound power
level*
1
Indoor Cooling/Heating
dB(A)
65 / 65 65 / 65 62 / 62 64 / 64
Outdoor
Cooling/Heating 67 / 67 69 / 69 67 / 67 69 / 69
Sound
pressure
level*
1
Indoor
Cooling (Hi/Me/Lo)
33 / 29 / 25 38 / 36 / 30 41 / 39 / 38 44 / 41 / 39
Heating (Hi/Me/Lo)
33 / 29 / 25 38 / 36 / 30 41 / 39 / 38 44 / 41 / 39
Outdoor
Cooling/Heating 54 / 54 57 / 55 54 / 54 57 / 55
Air flow
Indoor
Cooling (Hi/Me/Lo)
m
3
/min
19 / 15 / 10 28 / 25 / 19 16 / 14 / 12 26 / 23 / 21
Heating (Hi/Me/Lo)
19 / 15 / 10 28 / 25 / 19 16 / 14 / 12 26 / 23 / 21
Outdoor
Cooling/Heating 36 / 36 63 / 49.5 36 / 36 63 / 49.5
Exterior
dimensions
Indoor
HeightxWidthxDepth
mm
280 x 950 x 635 280 x 1,370 x 740 210 x 1,320 x 690 250 x 1,620 x 690
Outdoor
640 x 800 x 290 750 x 880 x 340 640 x 800 x 290 750 x 880 x 340
Net weight
Indoor
kg
34 54 37 49
Outdoor
45 57 45 57
Ref.piping size
Liquid/Gas ømm 6.35 / 12.7 6.35 / 15.88 6.35 / 12.7 6.35 / 15.88
Refrigerant line (one way) length m 30
Vertical height differences
Outdoor is higher/lower
m Max.20 / Max.20
Outdoor operating
temperature range
Cooling
°C
-15~46*
2
Heating -15~20
Air filter, Q'ty Filter kit : UM-FL2EF/UM-FL3EF (option) Pocket Plastic net x2(Washable)
Remote control (option) wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-E1R