Specifications
2524
R410A
RCN-KIT3-E
Wireless remote control (Option)
Dimensions : refer to page 18
FDC200VS
(8.0HP)
FDC71VNX
(3.0HP)
FDC250VS
(10.0HP)
FDC71VNP
(3.0HP)
FDC90VNP
(3.5HP)
OUTDOOR UNIT (1.5-10.0HP)
Installation workability
Enhanced installation workability thanks to the extended pipe length – longest level
in the industry and precharged refrigerant.
Refrigerant precharged piping length extends up to 30m. This eliminates the need to add refrigerant on site, which sets it free from trouble of
excessive or insufficient charging of refrigerant, and allows carrying out the installation smoothly. That of Hyper inverter 1.5~2.5HP & Standard
inverter is up to 15m.
Point
1
Piping length – 100m
(Hyper Inverter 4~6HP)
Point
2
Refrigerant precharged piping length extending to 30m
Hyper Inverter
Hyper Inverter
Micro Inverter
Micro Inverter
Standard Inverter
Standard Inverter
FDC125VNX
FDC125VSX
(5.0HP)
FDC140VNX
FDC140VSX
(6.0HP)
FDC100VNX
FDC100VSX
(4.0HP)
SRC40ZMX-S
SRC50ZMX-S
*
SRC60ZMX-S
*
(1.5HP~2.5HP)
*
SRC50/60ZMX-S is common for both of outdoor units of
SRK50/60ZMX-S (Residential Air-conditioners) and 1.5,
2, 2.5HP of Inverter Packaged Air-Conditioners.
Common components make for easy inventory control
and the installation procedure will be the same.
Due to application of blue coated fins (KS101) for the heat
exchanger of new outdoor unit, corrosion resistance has been
improved compared to current models.
Blue Fin (3~10HP)
This kit is recommended to be used in an area where the
lowest temperature drops below 0˚C.
Base heater kit (option)
CW-H-E1
applied for
FDC71VNX
FDC100~250VN,VS
FDC100~140VNX,VSX
Height
difference
(Outdoor higher
than Indoor)
Piping
length
Micro Inverter Standard Inverter
HP
1.5~2.5
3
4~6
30m
50m
100m
20m
30m
30m
Piping length
Height difference
50m
70m
30m
30m
Piping length
Height difference
HP
4~6
8
.
10
30m 20m
Piping length
Height difference
3
.
3.5
HP
FDC100VN
FDC125VN
FDC140VN
FDC100VS
FDC125VS
FDC140VS
(4.0HP~6.0HP)
Refer to our Technical Manual in detail
FDF
FLOOR STANDING
[ INDOOR UNIT ]
Micro Inverter
FDF 100/125/140
SPECIFICATIONS
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Powerful-Hi can be selected. Sound level:100VN(S)VD1 54dB, 125/140VN(S)VD 54dB
Air flow: 100VN(S)VD1 29m
3
/min, 125/140VN(S)VD 29m
3
/min
Installation workability (FDC200VS,250VS)
Using piping attachment that has flared connection and
brazed connection ends, there is no need conduct
brazing work inside the outdoor unit.
Brazed
connection
ø22.2mm
232mm
Flared
connection
ø19.05mm