Specifications

Graphic Operation Terminal GOT-F900 Creation of Display Screens 6
6-3
6.1.1 Functions dedicated to screen creation software FX-PCS-DU/WIN-E
The functions shown below are effective only when FX-PCS-DU/WIN-E is used.
These functions are not available when GT Designer is used.
1) Screen display
Indicator : A specified area on the screen can be inverted (or colors are replaced).
Buzzer : When a specified bit device in the PLC becomes ON, the buzzer of the
GOT sounds.
Data file transfer : When a specified touch key is pressed, the current value of the 16-bit
data register in the GOT is transferred to the data register (D) in the
PLC.
External character: Figures and symbols of 16
×
16 bits created by the user can be used.
Data change : The ten-key keypad can be displayed by pressing a touch key.
Indicator (screen) : When a bit device in the PLC becomes ON, a specified screen is over-
laid on the current screen.
2) Device comment
This device monitor function in HPP mode is used to display comments instead of devices.
(The comment display is available only in the F940GOT, F943GOT, and F940WGOT.)
#
Important point
Note:When the functions (1) to (3) above are used, they are treated as follows in GT
Designer.
- Read data to GT Designer
Screen data excluding functions (1) to (3) above is read.
When the data is read, screen data in the GOT main body is not changed.
- Write data to GOT
Functions (1) to (3) above cannot be set.
When data is written from GT Designer to GOT including functions (1) to (3) above,
functions (1) to (3) in the GOT are deleted. Accordingly, functions (1) to (3) should be set
again using FX-PCS-DU/WIN-E.