Specifications
Graphic Operation Terminal GOT-F900 Appendix 22
22-17
Restriction in set monitor in computer link for A Series
When a computer link unit for the A Series is attached to the QnA CPU and the GOT-F900 is
connected to the unit, the set monitor range is equivalent to that in the AnA CPU, and the
restriction shown in the table below is applied (by the restriction in computer link).
−
: Monitor and write disabled
Station number specification when configuring a Q multi-CPU system
The CPU station number is specified when setting devices.
0 : a connected CPU (a control CPU in a link connection)
1 to 4 : CPUs with individually specified station numbers
1) FX Series GM positioning unit (GM direct connection)
*1 Devices cannot be written.
Device name
Setting range Device
number
representation
GT Designer DU/WIN
Word
device
Timer
(
Present value
)
−
0 to 255
Decimal
Timer
(
Set value
)
−−
Counter
(
Present value
)
−
0 to 255
Counter
(
Set value
)
−−
File re
g
ister
−−
Device name
Setting range Device
number
representation
GT Designer DU/WIN
Bit
device
Input
(
X
)
X0~X377 X0~X377
Octal
Output
(
Y
)
Y0~Y67 Y0~Y67
Internal rela
y
(
M
)
M0~M511 M0~M511
Decimal
Special auxiliar
y
rela
y
(
SM
)
M9000~M9175 M9000~M9175
GOT internal bit re
g
ister
(
GB
)
GB132~1023 GB132~1023
Word
device
Data re
g
ister
(
D
)
D0~D8191 D0~D8191
Special data re
g
ister
(
SD
)
D9000~D3999 D9000~D3999
File re
g
ister
(
R
)
D4000~D6999 D4000~D6999
Index re
g
ister
(
Z, V
)
Z0~Z6
(
32 bits
)
Z
(
32 bits
)
V0~V6
(
16 bits
)
V
(
16 bits
)
GOT internal data re
g
ister
(
GD
)
GD100~1023 GD100~1023