Specifications

Graphic Operation Terminal GOT-F900 Changeover of Display Screen (GT Designer) 21
21-12
When ST. 1 is pressed, screen No. 2 is displayed.
When ST. 2 is pressed, screen No. 3 is displayed.
Setting of screen No. 1
ST. 1 key : Fixed value = 2
ST. 2 key : Fixed value = 3
• When the sequence program shown below is
executed while screen No. 2 is displayed, screen No.
10 or 20 is displayed by the base screen changeover
function.
Program example for application example 2
MEMO
"ST. 1" ke
y
When a PLC pro
g
ram is executed,
screen No. 10 or 20 is displa
y
ed.
ST. 2
Screen No. 1
ST. 1
MONI TOR
MONI TOR
* MENU *
"ST. 2" ke
y
To screen
No. 3
Screen No. 2
PROCESSING
STATION 1 MONITOR
MOV K1 D0
MOV K10 D0
Interlock is required so that the screen is not
chan
g
ed over to screen No. 10 or 20 while
screen No. 1 is displa
y
ed.
Initialization pulse
FX Series: M8002
A Series : M9038
MOV K20 D0
Screen No. 1 is displayed.
Screen No. 10 is displayed
Screen No. 20 is displayed