Specifications

Graphic Operation Terminal GOT-F900 Creation of Display Screen (GT Designer) 20
20-50
d) Number of devices
Enter the number of devices to which data in the GOT is to be transferred.
The number of devices (1 to 4000) set for recipe No. 1 is used for all other recipes
starting from recipe No. 2.
e) Edit key (for detailed setting)
This key allows setting of each recipe file in details.
1) Operations
Set b) Recipe Name, c) Device and d) Number of devices.
2) Read trigger
When a specified bit device turns ON or OFF, the contents of word devices starting
from the one set in c) Device as many as the number set in d) Number of devices are
transferred to the memory built in the GOT.
3) Write trigger
When a specified bit device turns ON or OFF, the data set in "4) Receipt device" are
transferred to word devices starting from the one set in c) Device.
4) Recipe device
Enter the value of a device to be written to the PLC.
When data is read using "2) Read trigger", this value is overwritten by the read value.
The write trigger cannot be omitted. The read trigger can be omitted when read is not
required.
#
##
#
Important point
Transfer from a personal computer
When the complete screen data is read from the personal computer, a data file containing the
Recipe, Alarm Conditions, Sampling Conditions, and System Settings is transferred to the
GOT along with the screen data.
The data file Read/Write characteristics vary per the GOT version as listed below.
Changes made to the data file in the GOT cannot be read from the GOT.
- F930GOT or F933GOT: prior to Version 4.30; F940GOT or F943GOT: prior to Version
6.30; F940WGOT: prior to Version 1.30.
Changes made to the data file in the GOT can be read from the GOT.
- F930GOT or F933GOT: Version 4.30 or later; F940GOT or F943GOT: Version 6.30 or
later; F940WGOT: Version 1.30 or later. "