Specifications

Graphic Operation Terminal GOT-F900 Creation of Display Screen (GT Designer) 20
20-14
3) Layout
When the number of digits to be displayed is smaller than the specified total number of
digits, the numeric is automatically shifted to the right, the center or the left in accordance
with the setting.
Example: When the specified total number of digits is set to 9 and the displayed numeric is
a 3-digit value
4) Gain 1, Gain 2 and Offset
The value obtained by the calculation "(Monitor value x Gain 1 / Gain 2) + Offset" is
displayed.
Example: When the monitor value is 1000 (current value of D100), the Gain 1 is set to 10,
the Gain 2 is set to 2 and the Offset is set to 3
(1000
×
10
÷
2) + 3
=
"5003" is displayed.
*
**
*
Display example
#
##
#
Important point
Display of numerics for timers and counters:
When a device whose numeric is to be displayed is set to a timer or counter, its current
value is displayed.
To display the set value of a timer/counter, specify indirectly the set value of the timer/
counter to be displayed as shown below, then display the value of the specified data
register.
1 2 3
1 2 3
1 2 3
Start point
Ri
g
ht
Center
Left
:
:
:
LINE 1
LINE 2
HEATING TIME
89.6 s
126.3 s
"Text" ob
j
ect
"Number" ob
j
ect
T0
D10
When T0 is specified as a device whose
numeric is to be displa
y
ed, the current value
of T0 is displa
y
ed.
When D10 is specified as a device whose
numeric is to be displa
y
ed, the set value of
T0 is displa
y
ed.