Specifications
Graphic Operation Terminal GOT-F900 Changeover of Display Screen (FX-PCS-DU/WIN-E) 19
19-16
19.7 Changeover to system screen
Function screens built in the GOT such as HPP MODE, SAMPLING MODE, ALARM MODE
and OTHER MODE can be displayed as user screens.
19.7.1 Display of system screen
This section describes the method to display a system screen as a USER SCREEN MODE
and the caution on this method.
• A system screen can be displayed by specifying a corresponding screen number
using the "Change Screen" object. (Refer to 22.4) Prior to this, "Save Current
Screen" should be made effective so that the previous user screen can be displayed
after the system screen.
• Screen No. 0 is created as follows.
The "Change Screen" object is set so that screen No.
1001 (DEVICE MONITOR screen) is displayed when
touch key No. 0 (DEVICE MONITOR) is pressed.
Change Screen
• For the operating procedures of each system screen,
refer to description on each mode.
• When the END key is pressed, the previous screen
(screen No. 0 in this example) is displayed again.
For the system screen number., refer to the appendix.
Condition
Screen
No.
(Direct)
Save Current
Screen
Control
Input
Bit Device
1
Touch key
No. 0
Not specified 1001 Not effective
Screen No. 0
* MENU *
"DEVICE MONITOR"
Screen No. 1001
DEVICE MONITOR screen
[ DEVICE MONITOR ] END
DEVI CE ON OFF
SET
COMMENT
DEC/HEX
Touch ke
y
No. 0
DEVICE MONITOR
Make sure to set "Save Current Screen"
effective.