Specifications
Graphic Operation Terminal GOT-F900 Creation of Display Screens (FX-PCS-DU/WIN-E) 18
18-41
*
**
*
Display example
• "NORMAL" or "HIGH!!" are displayed as the "Ascii" objects using three data registers D100
to D102.
When X0 becomes ON, "NORMAL" is displayed.
When X1 becomes ON, "HIGH!!" is displayed.
- "Ascii" object
Character Size: W:
×
2, H:
×
2
Word Device: D100
Data Length: 3
- Display
- Program in PLC
#
##
#
Important point
The "Ascii" object displays specified texts on one screen as shown above. Accordingly, the
screen is not required to be changed over or to be overlaid.
HIGH!!
LINE 1
NORMAL
LINE 1
"Text" ob
j
ect
"Ascii" ob
j
ect
Text
(
displa
y
color
)
B
g
(
back
g
round color
)
(
The broken line is not
actuall
y
displa
y
ed.
)
When X0 becomes ON When X1 becomes ON
*"LINE 1" is displa
y
ed as the "Text" ob
j
ect.
X0
MOV
MOV
MOV
H 4F4E
H 4D52
H 4C41
D100
D101
D102
FNC12
FNC12
FNC12
X1
MOV
MOV
MOV
H 4948
H 4847
H 2121
D100
D101
D102
FNC12
FNC12
FNC12
4F
4D
4C
4E
52
41
D100
D101
D102
(
H
)
(
H
)
(
H
)
Upper Lower
Stora
g
e status of data re
g
isters
49
48
21
48
47
21
D100
D101
D102
(
H
)
(
H
)
(
H
)
Upper Lower
Stora
g
e status of data re
g
isters