Specifications

Graphic Operation Terminal GOT-F900 Creation of Display Screens (FX-PCS-DU/WIN-E) 18
18-33
18.5.13 Library Image
The "Library Image" objects displays stored image in accordance with the current value or the
set value of a specified word device (T, C, D, V or Z).
As two or more images can be displayed on one screen, the number of screens can be saved.
*
**
*
Contents of setting
*
**
*
Display example
Image No. 5 or 10 is displayed in accordance with the executed sequence program.
Both the images are displayed from the same start position.
Each image is displayed as the same size as stored in the image library.
In the example above, if "Start No." is set to "10", image No. 15 (5 + 10) and image No. 20
(10 + 10) are displayed.
Attribute Contents of setting
Position Enter the X and Y coordinates in the unit of dot.
Bg and Fg
Enter the background color and the display color. (Initial values: White and
black)
Word Device
Enter a word device storing an image No. to be displayed.
Enter "Data Size" and "Displayed value" (Current of Preset) also.
Start No.
The monitored value plus this start No. are regarded as the image No. of an
image to be displayed.
"Librar
y
Ima
g
e" ob
j
ect
Displ a
y
ed value Current
Ima
g
e librar
y
Ima
g
e No. 5
100 W
×
100 H dots
Ima
g
e No. 10
100 W
×
100 H dots
Pro
g
ram in PLC
FNC12
MOV
K5 D200
Start
point
Displ a
y
screen
Ima
g
e No. 5 is transferred to
ima
g
e specification device
D200.
FNC12
MOV
K10 D200
Ima
g
e No. 10 is transferred to
ima
g
e specification device D200.
Bit Device
Data Size
Start No.
D200
16 bits
Current
0
Start
point
Displ a
y
screen