Specifications

Graphic Operation Terminal GOT-F900 Creation of Display Screens (FX-PCS-DU/WIN-E) 18
18-17
*
**
*
Display example
The displayed text is changed in accordance with the ON/OFF status of the limit switches
L1 to L3 provided in the carrying line shown below.
The "Library Text" object is used in this example. To specify a text No. stored in the library,
the data register D10 is used.
Program in PLC
Display in GOT
Workpiece
LS1
Zero point
LS2
Intermediate point
LS3
Final point
0
20
21
22
Zero point
Intermediate point
Finished
Text No.
-Library Text
Word Device : D10
Data Size : 16 bits
Displayed Value : Current
- Text library
MOV
LS1
LS2
LS3
MOV
MOV
K20
K21
K22
D10
D10
D10
Transfers text No. 20 to D10.
Transfers text No. 21 to D10.
Transfers text No. 22 to D10.
STARTING POINT POSITION
LINE
The displa
y
start point is fixed without re
g
ard to the len
g
th of the displa
y
ed text.
When switch LS1 turns ON, "Zero point" is displa
y
ed.
When switch LS2 turns ON, "Intermediate point" is displa
y
ed.
When switch LS3 turns ON, "Finished" is displa
y
ed.