Specifications
Graphic Operation Terminal GOT-F900 Test MODE 11
11-9
• Communication display
The model name with which communication is performed, is displayed.
Display item
Display Connected to
MELSEC-FX(CPU) When the GOT is connected to FX Series (CPU connection)
MELSEC-A(CPU) When the GOT is connected to A Series (CPU connection)
MELSEC-A, QnA(CPU) When the GOT is connected to A or QnA Series (CPU connection)
MELSEC-Q, QnA(CPU) When the GOT is connected to QnA or Q Series (CPU connection)
MELSEC-A(LINK) When the GOT is connected to A Series (computer link connection)
SYSMAC C(LINK)
When the GOT is connected to C Series manufactured by OMRON
Corporation (computer link connection)
FLEX-PC N(CPU)
When the GOT is connected to FLEX-PC N Series manufactured by FUJI
ELECTRIC CO., LTD. (CPU connection)
FLEX-PC N(LINK)
When the GOT is connected to FLEX-PC N Series manufactured by FUJI
ELECTRIC CO., LTD. (computer link connection)
AB SLC500(CPU)
When the GOT is connected to SLC500 Series manufactured by Allen
Bradley Co., Inc. (CPU connection)
AB MicroLogix(CPU)
When the GOT is connected to MicroLogix Series manufactured by Allen
Bradley Co., Inc. (CPU connection)
YASKAWA
CP9200SH(CPU)
When the GOT is connected to machine controllers manufactured by
YASKAWA Electric Corporation (CPU connection)
SIEMENS
S7-200 (CPU)
When the GOT is connected to S7-200 Series manufactured by Siemens AG
(CPU connection)
SIEMENS
S7-300(CPU)
When the GOT is connected to S7-300/400 Series manufactured by Siemens
AG (CPU connection)
MELSEC-FX(2PIF)
When the GOT is connected to a PC or two or more GOT units are connected
(Displayed only when the GOT is CPU-connected to FX Series.
Discrimination between the screen creation software and the ladder software
is not made.)
MELSEC-A(2PIF)
When the GOT is connected to a PC or two or more GOT units are connected
(Displayed only when the GOT is CPU-connected to A Series.
Discrimination between the screen creation software and the ladder software
is not made.)
MELSEC-A,QnA(2PIF)
When the GOT is connected to a PC or two or more GOT units are connected
(Displayed only when the GOT is CPU-connected to A or QnA Series.
Discrimination between the screen creation software and the ladder software
is not made.)
MELSEC-Q,QnA(2PIF)
When the GOT is connected to a PC or two or more GOT units are connected
(Displayed only when the GOT is CPU-connected to QnA or Q Series.
Discrimination between the screen creation software and the ladder software
is not made.)
PC(SCREEN DATA)
When the GOT is connected to a PC
(The GOT is connected to a PLC manufactured by other companies and no
2PIF function is used for connecting. The PC can use the screen creation
software only.)
FX-GM
When the GOT is connected to FX-10/20GM, FX
2N
-10/20GM and E-20GM
(CPU connection)