Specifications

Graphic Operation Terminal GOT-F900 Sampling MODE 9
9-5
9.2.1 SAMPLE COND.
Set the timing at which sampling is performed. When the sampling condition set here is
satisfied, a specified data register is accessed and its data is stored.
The sampling condition, trigger (DEVICE) or constant cycle (CYCLIC) can be selected.
Sampling by trigger
When X, Y, M, S, T or C becomes ON (OFF
(
ON) or OFF (ON
(
OFF) ,
sampling is performed. (D, Z and V cannot be specified.)
Sampling in constant cycle
A cycle (time interval) can be set within the range of 1 second to 10 days, 23 hours, 59
minutes and 59 seconds. Sampling is performed at the specified time interval.
*
**
*
Basic operation
CYCLIC
SET
SAMPLE COND.
Select "SAMPLE
COND.".
SET CONDITION
screen is displayed.
DEVICE
Select "DEVICE".
Screen 1 is
displayed.
Select "CYCLIC".
Screen 2 is
displayed.
1) Sampling by trigger 2) Sampling in constant cycle
1)
2)
Display the
device input
keyboard.
Device symbol Device No. ENT OFF -> ON
Execute
the input.
Change over
"OFF -> ON" and
"ON -> OFF".
Select a bit device among X, Y, M, S, T and C.
SET
Display the
ten-key pad.
0 to 9
Set date, hour, minute and
second. Set date, hour,
minute and second.
ENT
They are changed over alternately.
[ SET CONDITION ] END
SAMPLE COND.
M 0
DEVICE
SET OFF->ON
Screen 1
[ SET CONDITION ] END
SAMPLE COND.
0d 0h 0m 0s
CYCLIC
SET
Screen 2