Specifications
Graphic Operation Terminal GOT-F900 HPP Mode 8
8-18
Operation example
Changing the current value of data register D0 from 300 to 200, the current value of T1 from
263 to 300 and the set value of T1 from 1000 to 1500 by operating a touch key (Excluding the
F920GOT-K)
HPP MODE
screen
DEVICE MONITOR
Select "DEVICE
MONITOR".
D
16
Enter device
s
y
mbol "D16".
ENT
Move the
cursor to
D0.
Start
chan
g
e.
Execute chan
g
e
to "200" from
"300".
Refer to Fi
g
. 2.
Monitor D0
DEVICE 0
Displ a
y
D0.
Monitor of T1
DEVICE
Enter device
s
y
mbol "T".
T 1 ENT
Displ a
y
T1.
Refer to Fi
g
. 1.
Chan
g
e current value of D0
SET 2 0 0 ENT
Enter "200" as
new value.
Move the
cursor to
T1.
Chan
g
e current value of T1
Start chan
g
e
of the current
value of T1.
SET
3 0 0
Chan
g
e set value of T1
Start chan
g
e of the
set value of T1.
SET
1 5 0 0
Execute
chan
g
e to
"300" from
"263".
ENT
Enter "300"
as new
value.
Execute chan
g
e
to "1500" from
"1000".
ENT
Enter "1500"
as new
value.
Fi
g
.1
D 0
T 1 CUR
SET
[ 263]
[ 1000]
Fi
g
.2
CUR
SET
[ 300]
[ 1500]
[ 300] D 0
T 1
[ 200]
Section 5.3