Creating procedure in GT Designer
1) In "New Screen" in "Screen", display the screen creation window.
2) Change "Screen type" to "Window".
3) Input the screen "No." to be created.
(You can create up to 500 screens from No.1 to No. 500.)
The screen number you input here is treated as the decimal/hexadecimal/ASCII key
window screen No. in "Key Window Screen No." described in the previous section.
- Key window screen numbers are from 1 to 500 in the same way as base screens. "W" is
added to the number in the screen list in the test mode of the main body (Refer to
Chapter 11) so that the key window screen number can be distinguished from the base
screen number
4) Input the screen size.
- F940WGOT, F940GOT
X axis: Within the range of 94 to 318 dots in increments of 8 dots
Y axis: Within the range of 81 to 220 dots in increments of 8 dots
- F930GOT, F933GOT, F930GOT-K
X axis: Within the range of 10 to 240 dots in increments of 1 dot
Y axis: Within the range of 20 to 80 dots in increments of 1 dot
* Once you open the screen, you can enlarge or reduce the screen using the mouse by
selecting "Edit" in "Change Size" in "Screen".
5) You can put characters and touch keys on each key window screen in the same way as
base screens. However, the following objects are not available on key window screens.
- Numerical Input ("Numerical Display" is available.)
- Ascii Input ("Ascii Display" is available)
- Line Graph
- Alarm History Display
-Alarm List Display
- Trend Graph
6) Using GD12 as Numerical display, numerical or Ascii data can be displayed concurrently
while it is being input (Echo display).