Specifications

Graphic Operation Terminal GOT-F900 Creation of Display Screens 6
6-29
[ When data register D20 is assigned ]
*1 In F920GOT-K and F930GOT-K: From the first product, In F930GOT and F933GOT:
V4.00 or later, F940GOT, F943GOT: V6.00 or later, F940WGOT: V1.00 or later
Data register Contents of control
D20
D21
D22
Store the screen Nos. displayed in the screen mode.
D20: Stores the screen No. currently displayed.
D21: Stores the screen No. of the second screen when two or more screens are
overlapped (overlap window 1).
D22: Stores the screen No. of the third screen when three or more screens are
overlapped (overlap window 2).
D23 Stores the object ID whose input is completed.
D24
b0 Remains ON while the device assigned by the alarm function is ON.
b1 Remains ON while sampling is executed in the sampling mode.
b2 Turns ON when numeric value setting is completed.
b3 Turns ON when the battery of the GOT is deteriorated.
b4
Remains ON while the grip switch is pressed and held in the handy GOT (excluding
the robot handy GOT).
b5
Turns ON when the data read from the bar code reader is stored in the PLC.
When the bit 6 of the read device D
!
+0 is set to ON, the bit 5 of the write device
D
!
+4 is set to OFF.
b8
Remains ON while data is changed by numeric inputs or ASCII inputs.
*1
D25 to D34 Unused (Can be used as general word devices in sequence programs.)