User`s manual

6 - 78 6 - 78
6. HOW TO COMMUNICATE WITH ID TAGS
(5) Intelligent function module switch setting
The Intelligent function module switch setting of the remote I/O module at remote
I/O station is as follows.
When use intelligent function module switch setting in the default state, the
parameter setting is not necessary.
Slot Type Module name Switch1 Switch 2 Switch 3 Switch 4 Switch 5
0 Remote I/O Remote I/O QJ72LP25
1 0(*-0) INTERI EQ-V680D1 0004 0000 0000 0000 0000
2 1(*-1) INPUT QX41
3 2(*-2) OUTPUT QY41P
Switch Setting Items
b15
b3 b2 b1 B0
Switch1
0
Fixed
Write protect setting
0(OFF)
Enable
1(ON)
Disable
ID tag communication speed setting
0(OFF)
Standard mode
1(ON)
High-speed mode
Write verify setting
0(OFF)
Execute
1(ON)
Do not execute
b15
b3 b2 b1 b0
Switch
0
Fixed
Enable ch.2 Test mode
0(OFF)
Enable
1(ON)
Disable
Enable ch.1 Test mode
0(OFF)
Enable
1(ON)
Disable
Enable Y contact test request
0(OFF)
Enable
1(ON)
Disable
(6) Output mode at the time of the CPU error
The output mode at the time of the CPU error of the remote I/O module at remote
I/O station is as follows.
Output mode at the time of the CPU error Clear
Items are set in GX Developer.
Items are set in GX Developer.