6. HOW TO COMMUNICATE WITH ID TAGS
(2) Network parameters
The network parameters to set to a CPU module of the remote I/O master station
are as follows.
Unit 1
Network type MNET/H
Remote master
Starting I/O No.
0000
H
Network No. 1
Total stations 1
Mode Online
(3) Network range assignment
The network range assignment of the network parameter to set to a CPU module of
the remote I/O master station, are as follows.
M station -> R station M station <- R station
Y Y X X
Station
No.
Points Start End Points Start End Points Start End Points Start End
1 96 1000 105F 96 0000 005F 96 1000 105F 96 0000 005F
(4) Refresh parameters
The refresh parameters of the network parameter to set to a CPU module of the
remote I/O master station are as follows.
Link side PLC side
Dev. name Points Start End Dev. name Points Start End
Transfer SB SB 512 0000 01FF
SB 512 0000 01FF
Transfer SW SW 512 0000 01FF
SW 512 0000 01FF
Random cyclic LB
Random cyclic LW
Transfer 1 LB 8192 0000 1FFF
B 8192 0000 1FFF
Transfer 2 LW 8192 0000 1FFF
W 8192 0000 1FFF
Transfer 3 LX 96 1000 105F
X 96 1000 105F
Transfer 4 LY 96 1000 105F
Y 96 1000 105F
Items are set in GX Developer.
Items are set in GX Developer.
Items are set in GX Developer.