(4) Program conditions
(a) Setting contents
Setting Contents
Intelligent
Function Module
Device Address
Buffer Memory Name
Read Write
U0
\
G0
Command code specification
area (CH1)
H0 (Read) H1 (Write)
U0
\
G1
Communication specification
area (CH1)
K0 (Trigger)
U0
\
G2
Processing specification area
(CH1)
K0 (Data storage order: Upper -> lower
Calculation method: Addition
Calculation/Verification: Calculation)
U0
\
G3
Head address specification
area (CH1)
K10
(Address: 10)
K20
(Address: 20)
U0
\
G4
No. of processing points
specification area (CH1)
K8 (8 bytes)
(b) Devices used by user
1. External inputs (commands)
Device Application
M1010 Read ID Tag command
M1020 Write to ID Tag command
2. External outputs (verification)
Device Application
D1200 to D1203 Read data storage during Read ID tag
D1020 Error details storage