User`s manual
6 - 44 6 - 44
6. HOW TO COMMUNICATE WITH ID TAGS
6.4.8 Fill data
The Fill Data program is a program for initializing the data of an ID tag with specified
data.
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Buffer Memory Name Setting Contents
U0
\
G0
Command code specification
area (CH1)
H6 (Fill Data)
U0
\
G3
Head address specification
area (CH1)
K0 (Address: 0)
U0
\
G4
Number of processed points
specification area (CH1)
K0 (All data specified)
U0
\
G100
Data storage area (CH1) K0 (Fill data: 0)
(b) Devices used by user
1. External inputs (commands/data)
Device Application
M1070 Fill Data of ID Tag command
M1071 Fill Data of ID Tag result reception
M1072 Cancel Fill Data of ID Tag command
2. External outputs (verification)
Device Application
M1073 Normal completion during Fill Data of ID Tag
M1074 Module error during Fill Data of ID Tag
M1075 ID communication complete during Fill Data of ID Tag
D1070 Error details storage during Fill Data of ID Tag