Specifications

3 - 28 3 - 28
3. SPECIFICATIONS
3.8.5 Simple programming
This function allows you to simply import ECL2-V680D1 label information and use the
imported label names in the program, aiding in program streamlining and the prevention
of device input errors. For details on how to operate the engineering tool, refer to the
Mitsubishi Electric GX Works2 Operating Manual.
Point
When a CSV file for global labels created by device assignment verification is read and Convert/Compile is
executed, an error such as the following occurs:
"The label 'xxxxxx' is a data type that cannot be used in the ladder program, or the method of use is not
supported." (Error code C9526)
In this case, change the data type of the link register (RWw, RWr) in which the error occurred on the Global
Label Settings screen from word [unsigned]/bit string [16 bits] to word [signed], and execute
Convert/Compile.
Label names can be used
(Before change)
(After change)