Specifications
3 - 21 3 - 21
3. SPECIFICATIONS
(a) Read data storage range
The read data storage range is as follows according to the mode switch setting.
Table 3.21 Read Data Storage Area Range
Mode Switch Set
Value
Address Description Remarks
0 RWrm+3H to RWrm+FH Read data storage areas 1 to 13
Ver. 1 compatible, 4 occupied
stations, 13 points (26 bytes)
1 to 3 - - -
4 RWrm+3H to RWrm+7H Read data storage areas 1 to 5
Ver. 1 compatible, 2 occupied
stations, 5 points (10 bytes)
5 RWrm+3H to RWrm+FH Read data storage areas 1 to 13
Ver. 2 compatible, 2 occupied
stations, Expanded cyclic setting:
Double, 13 points (26 bytes)
6 RWrm+3H to RWrm+1FH Read data storage areas 1 to 29
Ver. 2 compatible, 2 occupied
stations, Expanded cyclic setting:
Quadruple, 29 points (58 bytes)
7 RWrm+3H to RWrm+3FH Read data storage areas 1 to 61
Ver. 2 compatible, 2 occupied
stations, Expanded cyclic setting:
Octuple, 61 points (122 bytes)
8 to F - - -
(b) Read UID storage range
The read unit identification number (8 bytes) when Read UID is executed is
stored in the read data storage areas 1 to 4 (RWrm+3H to RWrm+6H).
(c) Noise measurement result storage range
The measurement result (average value, maximum value, and minimum value
of measured data) when Measure Noise is executed is stored in the read data
storage areas 1 to 3 (RWrm+3H to RWrm+5H).
Table 3.22 Measure Noise Measurement Result
Address Area Description
RWrm+3H Read data storage area 1 Average value (0 to 99)
RWrm+4H Read data storage area 2 Maximum value (0 to 99)
RWrm+5H Read data storage area 3 Minimum value (0 to 99)
(d) Read initial data setting value storage range
The result (communication specification, communication setting, processing
specification, and auto system command wait time setting) when Read Initial
Data Settings is executed is stored in the read data storage areas 1 to 4
(RWrm+3H to RWrm+6H).
Table 3.23 Initial Data Set Value Read Results
Address Area Description
RWrm+3H Read data storage area 1 Communication specification (Refer to Section 3.6.1 (1).)
RWrm+4H Read data storage area 2 Communication setting (Refer to Section 3.6.1 (2).)
RWrm+5H Read data storage area 3 Processing specification (Refer to Section 3.6.1 (3).)
RWrm+6H Read data storage area 4
Auto system command wait time setting (Refer to
Section 3.6.1 (4).)