3. SPECIFICATIONS
(6) Error details storage area (RWrm+1H)
When an error occurs when the ID command execution request (RYn4) is turned
ON, the bit corresponding to the error contents turns ON.
When the ID command execution request (RYn4) is turned OFF, all the bits in the
error details storage area (RWrm+1H) are turned OFF.
Table 3.20 Error Details Storage Area
Bit Name Description
0 ID command error
Turns ON when there is an error in the specified initial data setting or the ID command.
Turns ON when the number of processing bytes is odd for read/write during ASCII/HEX
conversion.
1 Not used -
2 Not used -
3 Not used -
4 Not used -
5 Not used -
6 Not used -
7 ID system error 3 ID system error
8 ID system error 2 ID system error
9 ID system error 1 ID system error
10 Tag not present error Turns ON when there is no communicable ID tag in the antenna communication area.
11 Protect error Turns ON when data is written in an area set as write protected.
12 Tag communication error Turns ON when communication with an ID tag does not end normally.
13 Address error
Turns ON when an attempt is made to read or write data beyond the ID tag address
specifiable range.
14
Verify error
ASCII/HEX conversion
error
Turns ON when data writing cannot be performed normally with an ID tag.
Turns ON when reading is performed with ASCII/HEX conversion set to "With ASCII/HEX
conversion", and data that cannot be converted is included in the tag.
15 Antenna error Turns ON when failure occurs possibly because the antenna or amplifier is not connected.
(7) Read data storage area 1 and thereafter (RWrm+3H and thereafter)
These areas store read data when Read, Read UID, Measure Noise, or Read
Initial Data Settings is executed against ID tags.