Specifications
3 - 9 3 - 9
3. SPECIFICATIONS
Device No. Signal Name Description
RX(n+k)9
Initial data setting
complete flag
(1) Turns ON after initial data setting completion when the initial data setting request flag
(RY(n+k)9) is turned ON.
(2) Turns OFF when the initial data setting request flag (RY(n+k)9) is turned OFF and
received by the RFID interface module.
(3) For the timing chart, refer to "Initial data processing request flag (RX(n+k)8)".
RX(n+k)B Remote READY
(1) Turns ON after initial data setup is complete and the RFID interface module is ready
after power ON or reset.
(2) Turns OFF when the initial data setting request flag (RY(n+k)9) is turned ON and
received by the RFID interface module.
(3) Turns ON when the initial data setting request flag (RY(n+k)9) is turned OFF and
received by the RFID interface module.
(4) Turns OFF in TEST mode.
n: Address assigned to master station by station number setting.
k: Address assigned by set value of mode switch.
Implemented by the RFID interface module
Implemented by the sequence program
Initial data setting request flag
(RY(n+k)9)
Remote READY(RX(n+k)B)
Initial data setting complete
flag(RX(n+k)9)