Specifications
3 - 8 3 - 8
3. SPECIFICATIONS
Device No. Signal Name Description
RXn5 Error detection
[Initial data setting]
(1) Turns ON after storage of error details in error details (RWrn+1H) when the initial data
setting request flag (RY(n+k)9) is turned ON and an out-of-range value is specified in
the communication specification area (RWwm+0H) or the processing specification area
(RWwm+2H).
(2) Turns OFF when the initial data setting request flag (RY(n+k)9) is turned OFF and
received by the RFID interface module.
(3) The initial data setting complete flag (RX(n+k)9) turns ON even if initial data setup ends
abnormally.
(4) Does not turn ON when a watchdog timer error occurs. (The "RUN" LED turns off.)
RX(n+k)8
Initial data processing
request flag
(1) Turns ON after power ON or reset for a request for initial data setup by the RFID
interface module.
(2) Turns OFF when the initial data processing complete flag (RY(n+k)8) is turned ON and
received by the RFID interface module.
Implemented by RFID interface module
Implemented by sequence program
Clear Error command
Error details
Error occurrence
Clear Error execution
0
0
Initial data setting request flag
(RY(n+k)9)
Error details(RWrn+1H)
Error detection (RXn5)
Initial data setting complete flag
(RX(n+k)9)
Implemented by RFID interface module
Implemented by sequence program
Initialization execution
Initial data setting request
flag(RY(n+k)9)
Remote register(RWw)
Remote READY(RX(n+k)B)
Initial data processing
request flag(RX(n+k)8)
Initial data setting complete
flag(RX(n+k)9)
Initial data processing
complete flag(RY(n+k)8)