Specifications

3 - 4 3 - 4
3. SPECIFICATIONS
3.3 Functions
The RFID interface module has two operation modes: RUN mode and TEST mode.
The following describes the functions of each mode.
3.3.1 RUN mode
RUN mode is used during programmable controller operation.
Table 3.3 RUN Mode Functions List
Function Command Description Reference
Read
Read Reads data from an ID tag. Section 6.2.1
Read UID Reads the UID (unit identification number) of an ID tag. Section 6.2.4
Read Initial Data
Settings
Reads the Initial Data Settings. Section 6.2.6
Write Write Writes data to an ID tag.
*1
Section 6.2.2
Initialize Fill Data Initializes data of an ID tag with specified data. Section 6.2.3
Management Measure Noise Measures the noise environment around an antenna. Section 6.2.5
*1. Not compatible with data handled by Read with Error Correction, Write with Error
Correction, or Data Check of the EQ-V680D1/EQ-V680D2 RFID interface module.
3.3.2 TEST mode
TEST mode is used when set up the RFID system or when performing maintenance.
To set the mode to TEST mode, either set the mode switch located on the front of the
RFID interface module to TEST mode or set the test mode execution request (RYn5) to
ON in the sequence program.
Table 3.4 TEST Mode Functions List
Function
Description Reference
Communication test
Reads data from the ID tag.
Checks whether a sequence program, antenna, or ID tag caused a read error
when a data read error occurs with an ID tag.
Section 5.1.3(2)
Distance level
measurement
Checks the margin with respect to the maximum communication distance
(potential) of the installation distance of the ID tag.
Use this function to adjust the installation location.
Section 5.1.3(3)
Noise level
measurement
Checks whether noise that adversely affects communication with an ID tag is
occurring in the area surrounding the antenna installation location.
Section 5.1.3(4)