Specifications

3 - 1 3 - 1
3. SPECIFICATIONS
Chapter 3 SPECIFICATIONS
The following describes the RFID interface module general specifications, performance
specifications, remote Input/Output signals and remote register specification for the
master module.
3.1 General Specifications
Table 3.1 General Specifications
Item Specifications
Operating ambient temperature 0 to 55˚C
Storage ambient temperature -20 to 75˚C
Operating ambient humidity 10 to 90% RH, non-condensing
Storage ambient humidity 10 to 90% RH, non-condensing
Vibration resistance
JIS B 3502
and
IEC 61131-2
compliant
Frequency
Acceleration
Amplitude
Sweep
Coun
t
With
intermittent
vibration
5 to 8.4Hz - 3.5mm
10 times
each in X, Y,
Z directions
8.4 to 150Hz 9.8m/s
2
-
With
continual
vibration
5 to 8.4Hz - 1.75mm
-
8.4 to 150Hz 4.9m/s
2
-
Impact resistance
JIS B 3502 and IEC 61131-2 compliant
(147m/s
2
; 3 times each in X, Y, and Z directions)
Operating environment Free of corrosive gasses
Operating altitude
*1
0 to 2000m
Installation location Inside control panel
Overvoltage category
*2
II
Pollution degree
*3
2
*1. Do not operate the programmable controller at an altitude of 0m or greater in a
pressurized environment. Doing so results in the risk of malfunction
*2. This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises. Category II applies to equipment
for which electrical power is supplied from fixed facilities. The surge voltage
withstand level for up to the rated voltage of 300V is 2500V.
*3. This index indicates the degree to which conductive material is generated in
terms of the environment in which the equipment is used. Pollution level 2 is
when only non-conductive pollution occurs. A temporary conductivity caused by
condensing must be expected occasionally.