Specifications

6 - 38 6 - 38
6. HOW TO COMMUNICATE WITH ID TAGS
When data link startup by
buffer memory parameters
ends abnormally
M40 to M55BFM#10
Host data link status
Read other station data link status
(SW0080)
ECL2-V680D1 (Station No. 1) data link
in progress
ECL2-V680D1 (Station No. 1) data link
error
Read ECL2-V680D1 remote input (RX)
Set the communication specification
(RWw0) to "Trigger" (set value = 0)
Set the communication setting (RWw1)
to 0
Set the processing specification (RWw2)
to "Upper Lower" (set value = 0)
Set the auto system command wait time
setting (RWw3) to 0
Turn the initial data setting request flag
(RY79) ON
Turn the initial data processing
complete flag (RY78) ON
Turn the initial data setting request flag
(RY79) OFF
Turn the initial data processing
complete flag (RY78) OFF
Turn the Read ID Tag instruction ON
* Program for controlling remote device stations
* Initial settings
* Initial setting complete processing
* ID tag read processing