Specifications

6 - 35 6 - 35
6. HOW TO COMMUNICATE WITH ID TAGS
Turn the Write to ID Tag instruction ON
Write data specification (RWw3 to RWwF)
Store the error details (RWr1)
Set the command code specification
(RWw0) to "Write" (set value = 1)
Set the start address specification (RWw1)
of the ID tag for writing data to 40
Set the number of processing points
specification (RWw2) for writing data to
26 bytes
Turn the ID command execution
request (RY4) ON
Execute the ID command (Write)
Turn the ID command execution
request (RY4) OFF
Turn the Read ID Tag instruction OFF
Store the read data (RWr3 to RWrF)
Turn the Write to ID Tag instruction OFF
Add processing when an error occurs in the ID command here.
Add processing when Write ends normally here.
Add processing when Read ends normally here.
* ID tag write processing
* ID command complete processing
* ID command error processing
* End processing
* Write remote output signal