Specifications

6 - 30 6 - 30
6. HOW TO COMMUNICATE WITH ID TAGS
*1. The program in the dashed line section is required only if initial settings
are to be changed.
Read data link status
ECL2-V680D1 data link normal
ECL2-V680D1 data link error
Set the communication specification
(RWw0) to "Trigger" (set value = 0)
Set the communication setting (RWw1)
to 0
Set the processing specification (RWw2)
to "Upper Lower" (set value = 0)
Set the auto system command wait time
setting (RWw3) to 0
Turn the initial data setting request flag
(RY79) ON
Turn the initial data processing complete
flag (RY78) ON
Set the communication specification
(RWw0) to "Auto" (set value = 1)
Set the communication setting
(RWw1) to 0
Set the processing specification
(RWw2) to "Upper
Lower"
(set value =0)
Set the auto system command
wait time setting (RWw3) to 0
Turn the initial data setting
request flag (RY79) ON
Turn the initial data setting request flag
(RY79) OFF
Turn the initial data processing
complete flag (RY78) OFF
Turn the Read ID Tag instruction ON
*1
* Verify ECL2-V680D1 status
* Change initial settings
* Initial settings
* Initial setting complete processing
* ID tag read processing