Operating instructions
En-9
● OPERATING INSTRUCTIONS ●
Even if these items are checked, when the unit does not recover from the 
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated. •  Is the breaker turned on?
•  Is the power supply plug connected?
•  Is the ON timer set?  Page 7 
All LED lamps on the indoor 
unit are blinking.
•  Are the horizontal vanes installed correctly? 
 Page 8 
The horizontal vane does not 
move.
•  Are the horizontal vane and the vertical vane 
installed correctly?  Page 8 
•  Is the fan guard deformed?
The unit cannot be operated 
for about 3 minutes when 
restarted.
•  This protects the unit according to instruc-
tions  from  the  microprocessor.  Please 
wait.
Mist is discharged from the air 
outlet of the indoor unit.
•  The cool air from the unit rapidly cools mois-
ture in the air inside the room, and it turns 
into mist.
The swing operation of the 
HORIZONTAL VANE is 
suspended for a while, then 
restarted.
•  This is for the swing operation of the HORI-
ZONTAL VANE to be performed normally.
The air fl ow direction changes 
during operation.
The direction of the horizontal 
vane cannot be adjusted with 
the remote controller.
•  When the unit is operated in COOL or DRY 
mode,  if the operation  continues with  air 
blowing down for 0.5 to 1 hour, the direction 
of the air fl ow is automatically set to position 
(1) to  prevent water  from  condensing and 
dripping.
•  In the heating operation, if the air fl ow tem-
perature is too low or when defrosting is be-
ing done, the horizontal vane is automatically 
set to horizontal position.
The operation is stopped for 
about 10 minutes in the heat-
ing operation.
•  Defrosting  of  the  outdoor  unit  is  being 
done.
  Since this is completed in max.10 minutes, 
please wait. (When the outside temperature 
is too low and humidity is too high, frost is 
formed.)
The unit starts operation by 
itself when the main power 
is turned on, though it isn’t 
operated with the remote 
controller.
•  These models are equipped with an auto re-
start function. When the main power is turned 
off without stopping the unit with the remote 
controller and  is  turned  on again,  the  unit 
starts operation automatically  in the  same 
mode as the one set with the remote control-
ler just before the shutoff of the main power. 
Refer to “Auto restart function”  page 5 .
The operation does not stop, 
or air is blown even when the 
ON/OFF button is pressed.
•  Is  the  CLEAN  lamp  lighted?  When  the 
CLEAN lamp is lighted,  CLEAN  operation 
is performed.  Page 7 
CLEAN lamp is lighted. •  CLEAN operation is performed.  Page 7 
Multi system
The indoor unit which is not 
operating becomes warm and 
a sound, similar to water fl ow-
ing, is heard from the unit.
•  A small amount of refrigerant continues to 
fl ow into the indoor unit even though it is 
not operating.
When heating operation is 
selected, operation does not 
start right away.
•  When operation is started during defrosting 
of outdoor unit is done, it takes a few minutes 
(max. 10 minutes) to blow out warm air.
Outdoor Unit
The fan of the outdoor unit 
does not rotate even though 
the compressor is running. 
Even if the fan starts to rotate, 
it stops soon.
•  When the outside temperature  is low  dur-
ing  cooling  operation,  the  fan  operates 
intermittently to  maintain  suffi cient cooling 
capacity.
Water leaks from the outdoor 
unit.
•  During COOL and DRY operations, pipe or 
pipe connecting sections are cooled and this 
causes water to condense.
•  In the heating operation, water condensed 
on the heat exchanger drips down.
•  In the heating operation, the defrosting op-
eration makes water frozen on the outdoor 
unit melt and drip down.
Symptom Explanation & Check points
Outdoor Unit
White smoke is discharged 
from the outdoor unit.
•  In  the heating  operation, vapor generated 
by the defrosting operation looks like white 
smoke.
Remote controller
The display on the remote 
controller does not appear 
or it is dim. The indoor unit 
does not respond to the 
remote control signal.
•  Are the batteries exhausted?  Page 3 
•  Is the polarity (+, -) of the batteries correct?
 Page 3 
•  Are any buttons on the remote controller of 
other electric appliances being pressed?
Does not cool or heat
The room cannot be cooled 
or heated suffi ciently.
•  Is  the  temperature  setting  appropriate? 
 Page 5 
•  Is  the  fan  setting  appropriate?  Please 
change fan speed to higher setting. 
  Page 6 
•  Is the fi lter clean?  Page 8 
•  Is the fan or heat exchanger of the indoor unit 
clean?  Page 8 
•  Are there any obstacles blocking the air inlet 
or outlet of the indoor or outdoor unit?
•  Is a window or door open?
The room cannot be cooled 
suffi ciently.
•  When  a  ventilation fan  or  a  gas cooker is 
used in a room, the cooling load increases, 
resulting in an insuffi cient cooling effect.
•  When the outside  temperature  is high,  the 
cooling effect may not be suffi cient.
The room cannot be heated 
suffi ciently.
•  When  the  outside  temperature  is low,  the 
heating effect may not be suffi cient.
Air does not blow out soon in 
the heating operation.
•  Please wait as the unit is preparing to blow 
out warm air.
Airfl ow
The air from the indoor unit 
smells strange.
•  Is the fi lter clean?  Page 8 
•  Is the fan or heat exchanger of the indoor unit 
clean?  Page 8 
•  The unit may suck in an odor adhering to the 
wall, carpet, furniture, cloth, etc. and blow it 
out with the air.
•  During  PLASMA  operation,  you may  smell 
ozone that  is  generated in  small  quantities 
from the plasma electrode unit. This is not a 
malfunction.
Sound
Cracking sound is heard. •  This sound is  generated by the expansion/
contraction  of  the  front  panel,  etc.  due  to 
change in temperature.
The sound as burbling is 
heard.
•  This sound is heard when the outside air is 
absorbed from the drain hose by turning on 
the range hood or the ventilation fan, making 
water fl owing in the drain hose to spout out.
  This sound is also heard when the outside air 
blows into the drain hose in case the outside 
wind is strong.
Mechanical sound is heard 
from the indoor unit.
•  This is the switching sound in turning on/off 
the fan or the compressor.
The sound of water fl owing 
is heard.
•  This is the sound of refrigerant or condensed 
water fl owing in the unit.
Hissing sound is sometimes 
heard.
•  This is the sound when the fl ow of refrigerant 
inside the unit is switched.
In the following cases, stop using the air conditioner and consult your dealer.
•  When water leaks or drips from the indoor unit.
•  When the upper operation indicator lamp blinks.
•  When the breaker trips frequently.
•  The remote control signal is not received in a room where an electronic ON/OFF 
type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
•  Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
•  When an abnormal sound is heard.