Electric Heat Kit Installation Manual

4.5.E. Position the enclosure on top of the Air Handler so that the rear flange is inserted into the gap explained in step
4.5.D. Next, slide the heater enclosure back so that it is flush with the rear of the air handler
. The Angled Tab on the
Electric Heat Enclosure slides under the air handler’s rear flange on the supply side.
PVFY/PVA/MVZ
SVZ
Heater Enclosure will be

cabinet







4.5.F. Next, install the (2) M5 silver screws which are included in the accessory bag. This secures the electric heat
enclosure to the air handler
.
SVZ
PVFY/PVA/MVZ
Electric Heat Kit
Specifications are subject to change without notice. 20 © 2018 Mitsubishi Electric US, Inc.