To change mode switches, follow the steps below:
1. Disconnect power from the operator panel.
2. Set the mode switches using a ballpoint pen.
3. Reconnect power to the operator panel.
3.7.2 Cables
Most of the operator panels use the same type of flex cable connectors.
Flex cable connector
To release the flex cables from the connector, gently push the two flanges on the cable
connector towards the flex cable.
MODE
E1032, E1060, E1070, E1100, E1041, E1043, E1061, E1062, E1063,
E1071, E1101 and E1151
0000 “Run-mode” - Boot CE, normal operation.
0010 System Restore, resets the file system and registry, reinstalls the system pro-
gram (OPsys_bxxx.CAB). Restores the operator panel to factory settings.
Warning! Information can easily accidently be lost.
0100 Image Load mode (Sysload) allows upgrading of the firmware in the operator
panel.
Note: All files including the file system in the operator panel will be deleted
when upgrading with Image Loader.
1000 Service Menu mode, the service menu for the system program is shown.
Allows the user to set IP configuration, erase the project, calibrate the touch
screen, set the panel in Run/Transfer mode etc. See section 3.8 Service
Menu for details.
1100 Not used (Run-mode).
1110 Self-Test.
xxx1 Hard reset (forces the system to reset).
Note:
The connectors must be unlocked on both sides before removing the cable, otherwise
the flex cable may be damaged.
connector flanges