Installation manual

Chapter 8 PA Library
8-98
pa_def_esc
Function:
Memorizes each axis angle of current value as escape position.
Syntax:
long pa_def_esc(ARM armno);
armno Arm number (No.)
Explanation:
Memorizes each axis angle of current value as escape position.
Returns to default value when power supply is off.
Escape position default angles are:
S2: 45 [deg]
E1: 90 [deg]
W1: 45 [deg]
Others: 0[deg]
For escape position default angle correction method, refer to parameter setting.
Return value:
ERR_OK Normal termination
Others: Anomalous termination (Refer to error table)
Reference:
pa_set_esc Escape position alteration
pa_exe_esc Arm control to escape position