Installation manual

Chapter 6 Programming
6-121
Communication control (master) CPU status:
bit Error details Movement when
in anomalous
status
15
1:Non control mode
14
Control
Mode
0:Control mode
1:limit switch off
13
Limit switch
status
0:limit switch on
1:Switch on during teaching
12
Switch status
during teaching
0:Switch off during teaching
0x00 Normal
0x01
0x02 Anomalous EEPROM
0x03 Anomalous ARCNET initialization
Do not convert to
control mode (*1)
11 0x04 Anomalous CPU
| Occurring alarm 0x05 Anomalous upper controller
communication cycle
4 0x06 Anomalous power supply temperature
0x07 Anomalous 100V output
Converts to
adjustment/ stop
mode. (*1)
0x10 Anomalous other CPU
0x11 Emergency stop switch on
0x12 Dead man switch off
0x13 Limit switch on
Converts to
adjustment/ stop
mode.
1:Emergency stop switch off
3
Emergency stop
switch status
0:Emergency stop switch on
1:Generating 100V power
2
100V
generating status
0:Stop generating 100V power
1:Anomalous power supply temperature
1
power supply
temperature
status
0:Normal
1:Dead man switch on
0
Dead man switch
status
0:Dead man switch off
(*1) If alarm at 0x02~0x07 occurs in communication control CPU, it is different
from any other CPU anomaly. Servo CPU instantly stops arm motion with
“brake on/servo off.”