Installation manual

Chapter 6 Programming
6-64
The redundant axis control mode can be chosen on account of RMRC control. But,
depending on a redundant axis control mode to choose, each axis value for the restriction
data
– a parameter of “pa_odr_dpd” – has a different significance.
<Redundant axis control mode>
[No restriction] :For all axes restrictively controlled by 0.0[deg], a provided axis value
for the restriction data is ignored.
[All axes restriction] :All axes are restrictively controlled by a provided axis values for
the restriction data.
[S3-axis restriction]:In this mode, axis value means the one for the restriction data
when “pa_odr_dpd” is issued. The S3-axis is controlled by a S3 restriction axis value
inside the axis values for restriction data. For this reason, a movable angle issued within
a cycle has to be taken into account. Other axis values (except S3 axis value) for
restriction data are ignored and restricted to 0.0[deg].
[S3-axis interpolation]:In this mode, axis value means the target angle of S3-axis when
“pa_odr_dpd” is issued. The S3-axis is controlled by a S3 restriction axis value inside
the axis values for restriction data. For this reason, a movable angle issued within a
cycle has to be taken into account. Other axis values (except S3 axis value) for
restriction data are ignored.
[S3-axis fixation]:S3 axis angle is maintained as it is when RMRC real-time control was
started. For this reason, provided axis value for the restriction data is ignored.
Program Description: For 7-axis arm
Sets the time-out. :pa_set_tim
The default time-out is 1000 msec. This time can be issued only when it needs to be
altered.
Controls to the RMRC controllable position/orientation (each axis angl).:pa_exe_saf
Initializes the target position/orientation. pa_odr_dpd
If there is not a current target position/orientation, loads and sets the current ones.
Chooses the redundant axis control mode. pa_mod_jou
If not setting this mode, the prior set redundant axis control mode becomes available.
Sets the RMRC real-time control mode. pa_mod_dpd
Here comes the RMRC real-time control mode.
After issuing this PA library, until the RMRC real-time control mode is completed, the
command (pa_odr_dpd or pa_chk_cnt) has to be issued within time-out.
7- axis arm functio
n