Instruction manual

70
This menu is used to set the communication settings between
this unit and the external device connected.
RS-232C Setting
This item is used to remotely control this unit via a PC
connected to the RS-232C terminal.
COM/LAN1
1
RS-232C Setting
System Menu
step
1. Select the communication mode.
Remote A: Controls this unit via a PC and this unit
returns every status information.
Remote B:
Controls this unit via a PC and this unit
returns only the response to the command code.
Remote C:
Controls this unit via a PC and this unit
returns nothing.
Off: Does not control this unit via a PC.
step
2. Set the port settings shown below.
Transmission mode
Data bit length
Parity bit
Stop bit length
Delimiter
Set all the settings to the same values as the PC
connected.
COM/LAN
System Menu
RS-485 Setting
This item is used to make the settings to use this unit with
optional keyboard connected to RS-485 terminal.
COM/LAN1
2
RS-485 Setting
System Menu
step
1. Select the recorder address.
Standalone: Does not use the optional keyboard
with this unit.
Slave ID:01 to 16: Sets the ID number of this unit
when using with optional keyboard.