Specifications

St. David Catholic School Manning Architects
Gym and Classroom Replacement N10.024.00
New Orleans, Louisiana July 20, 2012
VIDEO SURVEILLANCE 16760 -6
1. Capability to archive to external HDD or DVD. Provide external HDD storage capacity
as required for 72 hours worth of images from 16 cameras per DVR, at a record rate of 1
PPS per camera.
G. Search Options:
1. Time and date
2. alarm number
3. bookmark
4. motion search.
H. Copy:
1. Capability to copy images to a HDD connected to USB ports or NAS port.
2. Capability for simultaneous copy, record, and playback.
3. Capability to apply a digital signature to all images, sequence of images recorded on the
4. DVR.
I. Scheduling Requirements:
1. User definable schedule to switch to day, night, weekends, and holidays. Schedule shall
support 2 user definable patterns.
2. Capability to allow user definable pattern settings for camera, record rate, record quality,
alarm record rate and quality, archiving, skip, and motion activation.
J. Alarm Functions:
1. Provide Alarm and Alarm Plus Normal activity-recording options.
a. Alarm shall record images from those cameras in an alarm activity condition.
b. Alarm Plus Normal shall prioritize the recording of those cameras in an alarm
c. activity condition, while recording images of none alarm cameras.
2. Capability to send a message on alarm or camera failure.
3. Emergency Alarm input, forcing alarm recording for all cameras.
4. Alarm log list for alarm activities when recorded as alarm on the hard disk, providing
5. time date, camera, and type of event.
6. Provide an alarm log searchable by time and date, camera type, and index, with a quick
search function playing back 5 seconds of the recorded information.(when Alarms are
recorded as Alarm).
7. Capability to protect alarm and activity recording on separate partitioning of the disk.
Partition shall be configurable in GB and have ability to overwrite itself.
8. Capability to notify up to 5 e-mail addresses or 5 IP addresses of an alarm occurrence.
9. Alarm Trigger Events:
a. DVR temperature.
b. Fan malfunction.
c. When an alarm is triggered.
d. Re-booting of DVR,