Specifications

St. David Catholic School Manning Architects
Gym and Classroom Replacement N10.024.00
New Orleans, Louisiana July 20, 2012
PA/INTERCOM SYSTEM 16750 -4
2.15.4 AM/FM CD Combination Player
2.16 Seventy-Two (72) paging zones and a dial on the fly group with two (2) priority levels of all
call capability. Paging into any one zone shall not interrupt any program(s) previously
distributed. If the areas receiving program are part of the page zone the program shall be
interrupted during the page and returned automatically when the page is completed. Each
group shall be able to have a custom name assigned to it simplifying programming of
multiple groups of speakers.
2.17 Nine (9) built in software definable signaling tones. A voice chip with the option for a male
or female voice, which shall be used to store custom messages, labels for rooms and custom
emergency tones. Voice announcements shall be automatically or manually at any time.
2.18 Two (2), three (3) or four (4) digit programmable architectural room numbers for
administrative and staff station locations.
2.19 The system shall be provided with voice-synthesized call-in, which provides any
administrative telephone audible annunciation of the calling parties location and architectural
room number.
2.20 Enhanced Caller I.D. information for use with all administrative phones. It shall be possible
to deliver industry standard enhanced Caller I.D. information to any third party phone
system providing seamless annunciation of room numbers and operation between systems.
2.21 Discriminating ringing to distinguish different levels of incoming calls.
2.22 Selective pre announce tones: a) Single chime-Page b) Dual chime-Intercom call c) or a
custom tone.
2.23 Call confirmation tone at the intercom speaker location when a call is placed. This tone
verifies that the call has been placed into the system queue. A second confirmation tone
shall be activated if the call is upgraded to an emergency call (See 2.31.3). Equipment, which
does not notify the caller that the system has accepted the upgraded call, shall not be
accepted.
2.24 Unanswered emergency calls shall, after a user-determined time, have their architectural
room number automatically announced over any one or group of speakers. This automatic
page shall notify nearby staff of an unanswered emergency condition and ensure staff
notification of the emergency situation.
2.25 The administrative telephone shall be a standard DTMF set. Any system requiring a "smart"
or proprietary type instrument shall not be acceptable. The administrative phone shall be
equipped with a 4 x 20 LCD display for visual display of incoming calls. The following
features shall be provided by the administrative telephone:
2.25.1 Three levels of system access:
a. Level 1 - Dialing of any administrative or speaker station, all call, emergency all call,
zone paging, scroll/erase call waiting queue, transfer and conference.
b. Level 2 - Same as Level 1 with select and distribute program capabilities, set/reset
alarm and relay functions.
c. Level 3 - Same as Level 2 plus the capability to bump or join a conversation in
progress and to access system set-up menu for all programming features.