Error indications
When an error occurs in the recorder, the log is registered in the log list. To clear the alert, press the CANCEL button.
*1 : Alert level
Minor : Check the cause of the alert. By clearing the alert, you
can keep using the recorder. If the same alert appears
frequently, contact your dealer.
Major : Contact your dealer.
*2 : (The following numbers are displayed in
.)
01 : CH 1 02 : CH 2 03 : CH 3 04 : CH 4
05 : CH 5 06 : CH 6 07 : CH 7 08 : CH 8
09 : CH 9 10 : CH 10 11 : CH 11 12 : CH 12
13 : CH 13 14 : CH 14 15 : CH 15 16 : CH 16
<Error log>
LOG number
LOG display
example in the
client software
Cause Remedy
Call-out
signal
output
Alert
level*1
5100 LOG5100 • The recorder is rebooted. • Press the CANCEL button on the
front panel to clear the alert.
Output Minor
5101
5121
LOG5101
LOG5121
• The recorder is rebooted for watchdog
operation.
- Output Minor
9900 LOG9900 • The HDD management information is
damaged.
- Output Minor
6100 LOG6100 • No HDDs can be recognized. • Check whether the HDD has no
malfunction.
• Turn off the power of the recorder
and then turn it back on.
• Check the connection.
Output Minor
6200 LOG6200 • No internal HDDs can be recognized. • Contact your dealer. Output Major
6400 LOG6400 • The HDD cannot be recognized during
mirroring mode.
• Check whether the HDD has no
malfunction.
• Turn off the power of the recorder
and then turn it back on.
• Check the connection.
Output Minor
1400 LOG1400 • An error occurs during recording. • Check whether the HDD has no
malfunction.
Output Minor
2400 LOG2400 • An error occurs during data acquisition. • Start the operation again.
• Turn off the power of the recorder
and then turn it back on using the
POWER button on the front panel.
• Turn off the power of the recorder
and then turn it back on using the
MAIN switch on the rear panel.
• Press the CANCEL button on the
front panel to clear the alert.
Does not
output
Minor
1500
1600
LOG1500
LOG1600
• An error is detected in the data stored in
the HDD.
• Check the HDD. Does not
output
Minor
1300
2300
LOG1300
LOG2300
• An error occurs during writing/reading
the HDD.
• The HDD is exposed to vibrations and
shocks.
• When no abnormality is found, you
can keep using the recorder.
• When errors occur repeatedly, check
the HDD and cables and reboot the
recorder.
Does not
output
Minor
54
*2 LOG54 *2
• The IP camera is not connected correctly. • Press the CANCEL button on the
front panel to clear the alert.
• Check whether the recorder and
camera are connected correctly and
turned on.
Output Minor