Instruction manual

18
Troubleshooting
Illumination status of indicators
The indicators on the front panel of the recorder blinks or illuminates, showing the condition of the recorder as shown in the table
below.
POWER REC
ALARM
REC
ALERT IP-CAM
MIRRORING
SELF
TEST
Green Red Red Amber Green Green Green
HDD operation
mode
Mirroring
Spanning
Error
Error after
startup
Normal (no error)
LAN LINK error
Error
Camera
connection
No camera connected
Connection error
Camera connected
Self test Executing
Error detected
No error detected
Error during
startup
HDD recognition error
Error occurred or no response returned during
reading-out of the management information
Not formatted
: The indicator goes out.
: The indicator illuminates.
: The indicator blinks.
Checking the status of the recorder
<Self test function>
This recorder uses many electronic parts and HDDs and malfunction may occur in them. By checking the status of the recorder
(faulty or normal) using the self test function, you can nd a malfunction, if any, at an early stage and prevent the recorder from
remaining faulty.
Step
1 Press the SELF TEST button on the front panel of the recorder.
The indicator on the button blinks during self test. It illuminates when no error is detected.
When the indicator goes out, the error is detected. Consult your dealer.