User`s manual

4-27
4.5 Command Execution Example
INP-TN5A0202-E
Reading out set values to the monitor area
When “0003h” is set to the reading demand ag (No. D1000), “Control module (St. No. 1)’s Ch. 1 SV value” is read to the data
eld in the monitor area, and “0003h” is set to the reading response ag (No. D0000).
(1) Indicate reading “Ch1 SV value”
by setting “0003h” to the reading
demand flag.
Temperature control module
St.1
PLC
(3) If completed reading out,
“0003h” will be set to the
reading response flag.
Register contents
Value
Ch1 PV value 100.0°C
200.0°C
Ch1 SV value
Ch1 PV input
100.0°C
Device memory
Setting area
D1000
D1001
D1002
D1003
D1004
Reading
demand flag
System
area 1
Ch1 SV
value
Parameter
setting
demand flag
Command
setting
demand flag
0003h
0000h
0000h
0000h
0
(0.0°C)
Monitor area
D0000
D0001
D0002
D0003
D0004
0003h
0000h
0000h
0000h
2000
2000
(200.0
(200.0
°C
)
Reading
response flag
System
area 1
Ch1 SV
value
Parameter
setting
response flag
Command
setting
response flag
(2) Read out entered set value
(Ch.1 SV value) in the setting
area data field to the monitor
area data field.
Content
Programless
communication
module
After reading out, set “0000h” (Stop operation) to the reading demand ag (No. D1000) to put the programless communication
module’s reading demand into the standby status. When the reading demand comes to be in the standby, “0000h” is set to the
reading response ag (No. D0000).