User manual
3 PLC Communication
© Copyright Reserved Autonics Co., Ltd. 83
3.4.3 GP, LP configuration
3.4.3.1 Mono type
Before downloading drawn data from GP Editor: Synchronize communication configurations of
between GP/LP and GP Editor. (Refer to ‘3.1.2.1 Mono type’.)
1st After downloading drawn data from GP Editor, enter system setting menu.
Touch left-upper point as default position of system setting menu.
2nd Select [SET ENVIRONMENT]-[PLC SETTING].
3rd CH1 protocol is set as LS MASTER K200 as PLC type from GP Editor. CH1 is
designated as LS MASTER-K200 and CH2 is designated as MITSUBISHI FX2N from
GP Editor.
4th CH2 protocol is set as MITSUBISHI FX2N as PLC type from GP Editor but
downloaded MITSUBISHI FX2N protocol is not applied directly. (Communicates with
EDITOR from CH2).
Touch protocol display item of CH2 to set MITSUBISHI FX2N.
5th To communicate between GP/LP and LS MASTER K200 for CH1, MITSUBISHI
FX2N for CH2, desigante the connect port for the specific PLC and use the dedicated
cable. (Refer to ‘4 Communication Cable By Device’)