3 PLC Communication
54 © Copyright Reserved Autonics Co., Ltd.
8th To communicate between GP/LP and Autonics CT6M-2P for CH2, designate the
connect port for the specific PLC and use the dedicated cable. (Refer to ‘4
Communication Cable By Device’)
In case of Autonics CT6M-2P, it uses RS422 port. Set connect port item of CH2 as
‘RS422’. Connect port display rotates in order as RS422↔RS232C with touching.
9th Synchronize the station of between GP/LP and Autonics CT6M-2P. The station of
CH2 is set from link device of GP Editor. (Refer to ‘1.4 Link device’.)
Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow
control) of between GP/LP and Autonics CT6M-2P.
The communicate specification of downloaded PLC to GP/LP is set as default of the
connected PLC and communication is available directly. (Only when the
communicate specification of connected PLC is set as default)
Touch ‘CH2’ and detailed configuration screen is switched. Designate detailed
configuration.
10th After completing communication configuration, you should exit system setting menu
and switch user screen to communicate GP Editor.
Touch ‘Menu’, current setting values are saved and it returns to previous menu.
Touch ‘Exit’, current setting values are saved and it returns to user screen.